home Marine Products
FuelAir
Separators Fuel FilterWater Separators
Gasoline Series 99102
Diesel Spinon Series 104109
Series MC7 110113
Turbine Series 114133
Hydraulic Filters 134137
Liquid Transfer Systems Series FuelAir Separators 142143
Drinking Water Filters 144145
Air Filtration 146147
Marine Accessories 148150
Discontinued Models 151
s Selection
s Index
Turbine Series
SELECTION
SECTION 2
DIESEL KEROSENE AND GASOLINE FUEL Most products in this section are Underwriters Laboratories Listed for Marine use and many
are USCG Accepted or meet ASTM Specification F 1201 Documentation or certification is
available upon request
1 Find the application Diesel 2 Kerosene or Gasoline
2 Find the installation Will the unit be installed on the suction vacuum or pressure side of the
fuel pump Racor units are most efficient when installed on the suction side of the fuel system
If the filter is a replaceable engine spinon type go directly to the 320 Engine Spinon Series
3 Find the total fuel flow rate This is the total flow that will pass through the filter
You may obtain this information from your engine or equipment manufacturer or your
Racor dealer Use this information to select a Racor filter that has a greater flow rating than your
equipments total fuel flow rate
If this information is not available use the following formula for estimating
Diesel or kerosene fuel systems
Gallons per Hour is Engine Horsepower maximum multiplied by 18 or GPH HP X 018
Gasoline fuel systems Gallons per Hour is Engine Horsepower maximum multiplied by 10 or GPH HP X 01
Gasoline fuel systems fuel injected
Use a straight 40 GPH figure Smaller outboards will use a 25 GPH figure
4 What other conditions apply
Water A water detection package should be added to inform the operator of water
buildup and necessary servicing Water detection packages are available for use with all models
in diesel fuel applications only
Does the engine need to run continuously not allowing a shutdown for needed servicing such
as a generator If so see Turbine models with the 75 or 79 prefix in the part number
What type of filter element best suits your vessel The Turbine series have element cartridges
that are serviced from the top and all other units in this section have a removeable spinon type
cannister that is serviced from the bottom
A convenient feature may be a head mounted hand operated priming pump See models
215MAM 230MAM and 245RMAM as well as 445MAM 460MAM 490MAM and 4120MAM
models
5 With the above information review the models suggested that best fit your Most of the Model Groups have additional information to help in
identifying the exact model for
your needs Call your Racor distributor or Racor customer service if you need additional
assistance at 800 3443286 or email us from our website at TRANSFER SYSTEMS
FUEL AIR SEPARATORS and
DRINKING WATER FILTERS
1 Go directly to those Sections for specific selection 92
SECTION 2 Index
Marine Products Index
Fuel FilterWater Series Application Installation Flow Rate 02 Outboards
Suction 25 GPH 95 LPH InOutboards 25 95
Outboards
InOutboards
Outboards
Suction
Suction
Suction
95 97
95 97
9899
02 Outboards Both Suction 60 227 98 02 Outboards Both Suction 90
341 98 Both Suction 120 454 98 102
Diesel Spin
on Series
110A Diesel 15 57 Diesel Suction
15 57 105 107
215 230 245RMAM Diesel Suction 153045 57114170 105 108
445MAM 460MAM Diesel Suction 4560 170227 105 109
490MAM 4120MAM Diesel Suction 90120 341454 105 109
Series MC
60MC 90MC 180MC Diesel Suction 6090180 227341454 75180MC 79180MC Diesel Suction
180360540 68113632044 Series
500MA Diesel Suction 60 227 Diesel
Suction 90 341 115 Diesel Suction 180 681 115
Diesel Suction 360 1363 115 Diesel Suction
120 454 115 Diesel Suction 180 681 115
Diesel Suction 360 1363 115 Diesel Suction 540
2044 115 Diesel Suction 540 2044 115 Filters
Racor Marine Hydraulic Filters Pressure See product listings Breathers Adapters
137
Liquid Transfer FuelOil Filter System Pressure 240 908
Air Gasoline Fuel tank vent line 12 CFM 90 GPM Fuel tank vent line
17 CFM 127 GPM Water Sediment Removal Pressure 6 GPM 23 LPM
Taste and Odor Pressure 3 GPM 12 LPM Engine Air M408512 AF M501012 and AF M601212
See product listings Models
Marine Accessories 148151
Marine Gasoline Series Boats with Inboard Gasoline Engines
1 Power boats with inboard gasoline engines must use units equipped with metal bowls
2 Stock carbureted engines can use all units
or high performance engines or severe service applications should use units with a flow rate
between 40 to 120 gallons per hour GPH
Consult the engine manufacturer for the exact fuel filter flow rate
3 For boats where a fuel filterwater separator is already installed
This is generally a MerCruiser or OMC style filter fuel ports on top of filter head
Use the B32020MAM MerCruiser or B32021MAM OMC
If there are no filters already installed specify the 320RRAC or 660RRAC units For
boats the is IMPORTANT All units must be installed on the suction vacuum side of the fuel or transfer pump
Power Boats with Outboard Gasoline Engines
1 Power boats with outboard gasoline engines can use either seethru blue bowls or metal bowls
2 Stock carbureted engines can use all units
High performance engines or severe service applications should use units with a flow rate between 40 to
90 gallons per hour GPH
3 For boats where a fuel filterwater separator is already installed
This is generally a Quicksilver or OMC style filter fuel ports on top of filter head
Use the B32013 Quicksilver or B32014 OMC
If there are no filters already installed specify the 320RRAC or 660RRAC units For
boats the is IMPORTANT All units must be installed on the suction vacuum side of the fuel or transfer Powered Boats
Continuous Operation
1 For engines that must run continuous andor cannot be shutdown for servicing specify only MAVM or
MAXM units with metal bowls found under Fuel FilterWater Separators Turbine Series which follows
this series
All other boats that are routinely serviced daily may specify any series model with a metal Along with the information you obtained in SECTION 2
SELECTION page 94 consider the
following Are there any space limitations in the available location The location should provide
adequate space for removing the element draining off contaminants from the bowl
2 What filtration rating is needed Gasoline spinon filters are standard with 10 micron media
Turbine models can be ordered with 2 10 or 30 micron media
Using this information select a unit from the next page or check the models which follow to
find just the right unit for your additional information call your Racor dealer or call Racor customer service 800 3443286
6 AM to 5 PM Pacific Time or email us from our website 94
Marine Gasoline Series
2
B32013
025RAC01 B32014
025RAC02 025RAC05 B32020MAM
Notes
1 025RAC01 and 025RAC02 are for outboard engine applications only
2 B32013 B32014 model with blue seethru bowls are for outboard engine applications only
3 MAM metal bowl units are approved for gasoline service UL For additional information and availability contact customer service 800 3443286
6 AM to 5 PM Pacific Time or email us from our website
BASIC MODELS 025 RAC 01 025 RAC 05 B32013 B32020MAM
025 RAC 02 B32014 B32021MAM
Maximum GPH 25 25 60 60
Flow Rate LPH 95 95 227 227
Filter Element S2501 NA S3213 S3220UL
Part Numbers S2502 S3214 S3220UL
Filter Element NA NA 111616 111616
Center Threads NA 112 112
Head Port Size NA NA NA
Height in 431 475 675 675
mm 109 121 171 171
Width in 225 230 Dia 375 Dia 375 Dia
mm 57 58 Dia 95 Dia 95 Dia
Depth in 210 230 Dia 375 Dia 375 Dia
mm 53 58 Dia 95 Dia 95 Dia
Weight dry Lbs 03 027 12 16
kgs 014 012 054 073
Clean Pressure PSI 026 035 25 0611 061
Drop kPa 18 24 172 423 1 423
Max Pressure PSI 100 30
Element Removal
Underbowl in 1 NA 1 1
Clearance mm 254 254 254
Operating Temperature Temp 2 40o 255o F 40o 121o C
1 Acquired using 320RRAC mounting head
2 025RAC Series Operating Temperature 10o 180o F 23o 82o C
Marine Gasoline Series 025
0102 025
are found on the introduction page
How to Order
The example below illustrates how the part numbers are 025 RAC 02
25 GPH optimum flow rate Filter Media
Cast aluminum mounting head with 14NPT inlet 01 250 micron plastic fuel
straining element S2501
and outlet fuel ports Features one hole for
Not for water removal
mounting with up to a 14 diameter capscrew 02 10 micron Aquabloct
Reusable spinon seethru collection bowl filter element S2502
WARNING FOR OUTBOARD ENGINES PERSONAL WATER CRAFT AND OTHER
APPLICATIONS DO NOT USE THIS FILTER WITH INBOARD ENGINES OR STERN
DRIVE BOATS USE RACOR UL LISTED MARINE FILTERS SEE Service Parts
Elements include replacement bowl O ring
Note Replace filter annually or at the first indication of power loss whichever comes Always keep an extra filter element
on hand
025 RAC 01 use S2501 250 micron plastic fuel straining element
025 RAC 02 use S2502 10 micron Aquabloct filter element
31391 Replacement See
thru Bowl
31185 Replacement Bowl Oring only for both Graphs
Results are from controlled laboratory tests Field results may vary
100 05 8
75 10 mic 04 10 mic 6
Percent PSI 02 PSI 4
Efficient 250mic
25 01 250mic 2 10 mic
0 00 0
0 50 100 150 0 10 20 30 40 00 05 10 15
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction Racor Gasoline Solids Capacity Test
PSI X 2036 inHg PSI X 6895 kPa using Fine Test Dust 25 GPH
025 RAC 05 Features
Inline Filter 25 GPH
D All Stainless Steel construction
516 Hose beads on inlet and outlet fuel D Black E coating for corrosion
ports with 10 micron filtering media Secure protection
D Only 25 PSI restriction 25 GPH
hoses with hose clamps not provided D Can withstand up to 30 Information
This filter may be used in all suction vacuum side fuel system installations or in pressure
side installations up to 30 PSI
The filter should be replaced annually or if there is a noticeable loss of power whichever
comes first Always carry a spare filter onboard as one tank full of contaminated fuel can 025RAC05
easily plug a filter
Marine Gasoline Series B3201314 are found on the introduction page
B32013
How to Order The blocks below detail the features of these units Underwriters Laboratories
Recognized Component B32014
B32013 B32014 B32020MAM B32021MAM
60 GPH
Fits 111616
Quicksilver heads
60 GPH
Fits 112
OMC heads
60 GPH Fits 111616
Mercruiser mounting
heads S3220 10 micron
60 GPH Fits 112
OMC mounting heads
S3221 10 micron
S3213 10 micron S3214 10 micron Aquabloct media with Aquabloct media with
metal collection bowl metal collection bowl
blue seethru blue seethru and 38 drain plug and 38 drain plug B32020MAM
collection bowl collection bowl UL Recognized Component UL Recognized Component B32021MAM
For outboard For outboard
engine applications engine applications For inboard or outboard For inboard or outboard
only only engine applications engine Cross Reference Chart for Racor units with bowls
Note For replacement filter elements only see item 1 in parts list below
Aquapower RACOR PCM RACOR
6001 B32013 R080020 S3228UL
without bowl
6031 B32020
Sierra
6040 B32014 B32021 187845 B32013
1807850 B32020MAM
Baldwin
BF791 B32013 B32020MAM Suzuki US
991052004 S3227
without bowl
Fram Volvo
PS3808 B32013 B32020MAM 855686
2 B32020MAM
Quicksilver Mercury Marine Wix
35807172 35604941 B32020MAM 33225 B32013
358052691 35807172 358052691 B32013 B32020MAM
Yamaha
OMC B32013
502905 B32014 S3220UL
174144 B32021MAM without bowl
Parts List
ItemPart No Description Case Qty 375
95 mm
1 20707 Oring gasket pack all units 1 1
2 S3213 B32013 Element 10 micron 12
S3214 B32014 Element 10 micron 12
S3220UL B32020 Element 10 micron 12 2
S3221UL B32021 Element 10 micron 12
3 RK30747 Seethru Blue Bowl shown 1
RK3047302 Metal Bowl NPT plug white 1 171 mm
Top View showing
powder paint coating MAM 1 center threads
4 RK30476 Plastic Drain Knob 1 3 S3213 S3220UL
RK22099 Drain Gasket 111616
4 S3214 S3221UL
918N6 Metal Plug 38 NPT MAM 1 112
Marine Gasoline Series
320RRAC02
660RRAC02 side Notes
1 and 660RRAC01 with blue seethru bowls
are for outboard engine applications only
3 MAM metal bowl units are approved for gasoline service UL 660RRAC02 and are approved for
inboard engine or outboard engine gasoline service UL Listed
5 For additional information and availability contact customer service 800 3443286
6 AM to 5 PM Pacific Time or email us from our website BASIC MODELS 120R RAC 01 320R RAC 01
660R RAC 01 3120R RAC 32
320R RAC 02 660R RAC 02
Maximum GPH 30 60 90 120
Flow Rate LPH 114 227 340 454
Filter Element S3240 S3227 S3232 S3232UL
Part Numbers S3228UL S3232UL
Center Threads M18 X 15 114 114 114
Head Port Size Height in 65 938 1100
1038
mm 166 238 280 264
Width in 32 4 42 4
mm 81 102 106 102
Depth in 32 4 45 5
mm 81 102 114 127
Weight dry Lbs 11 2 3 2
kgs 05 090 14 090
Clean Pressure PSI 015 061 061 015
Drop kPa 103 423 423 103
Max Pressure PSI 7
Element Removal
Underbowl in 1 1 1 1
Clearance mm 254 254 254 254
Operating Temperature 40o 255o F 40o 124o C Temp1
1 Operating Temperature 10o 180o F 23o 82o C
Marine Gasoline Series Model 120R
are found on the introduction page
How to Order
120R RAC 01
Fuel Filter Water Separator Assembly This unit is designed for smaller gasoline
applications and may handle fuel flows up to 30 gallons per hour GPH The
assembly has an anodized base plating and is then coated with a durable
applied powder coating for superior corrosion resistance The
spinon filter design is simple to replace and the reusable plastic contaminant
collection bowl features a selfventing drain valve for removing unwanted Service Element 12 per case element seals included
Element Part No Micron Rating
S3240 Graphs These results are from controlled laboratory tests Field results may vary
04 120R
100 8
75 03 6
Percent 50 PSI 02 PSI 4
Efficient 25 01 2
0 00 0
0 50 100 150 0 10 20 30 0 10 20 30 40 50
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A S3240 Pattern Parts List The circled number corresponds to the item
number shown below
Not to scale
140 78 mm
36 mm ItemPart No Description Case Qty
1 RK1021401 Head 14 NPTF Ports 1
516 8 mm diameter
918N4 14 steel port plugs 1
clearance for fasteners 2 S3240 Service Element 10 micron 12
3 RK10012 Bowl Oring 1
2 4 RK10222 Seethru Bowl Drain 1
65 5 RK30476 Drain Valve Assembly 1
166mm 10223 Installation Instructions
Head top view
The fuel ports
are 1418
NPTF SAEJ476 5
Marine Gasoline Series Models 320R
are found on the introduction page
How to Order
The example below illustrates how the part numbers are 320R RAC 01
Basic Model 60 GPH Bowl Three port head with 14 NPT 01 for Seethru bowl outboard engine use only
tapered pipe threads anod 02 for Metal bowl inboard or outboard engine
ized base plating and white use UL MARINE LISTED
powder paint coating Service ELEMENT INCLUDES
REPLACEMENT TOP AND BOTTOM SEAL
320R
01 use S3227 10 micron
320R
02 use S3228UL 10 micron UL Recognized Hole Pattern Parts List LISTED
ItemPart No Description Case Qty
1 OUT
1 RK20180 Mounting Head 1 200
51 mm
2 20707 Oring gasket pack all units 1 2
3 S3227 01 Element 10 micron 12 38 10mm diameter
clearance for fasteners
S3228UL 02 Element 10 micron 12 3
4 RK30747 01 Seethru Blue Bowl shown 1
RK3047302 02 Metal Bowl and NPT plug 2
White powder paint coating 1
5 RK30476 01 Drain Knob 1
918N6 Steel port Plug 38 NPT 1 5
22237 Installation Instructions Head top view Fuel ports are
1418 NPT Graphs These results are from controlled laboratory tests Field results may vary
100 100 8
75 075 6
50 PSI 050
Percent PSI 4
Efficient 25 025 2
0 000 0
0 50 100 150 0 15 30 45 60 0 10 20 30 40 50 60 70
Time Minutes Flow GPH Grams
SAE J905 Fuel Flow Restriction Racor Gasoline Solids Capacity Test
SAE J1839 Water Separation
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 10 100
Marine Gasoline Series Models 660R
are found on the introduction page
How to Order
The example below illustrates how the part numbers are 660R RAC 01
Basic Model 90 GPH Bowl Four port head with 38 NPT 01 for Seethru bowl outboard engine use only
tapered pipe threads anod 02 for Metal bowl inboard or outboard engine
ized base plating and white use UL MARINE LISTED
powder paint coating Service ELEMENT INCLUDES
REPLACEMENT TOP AND BOTTOM SEAL
660R
01 use S3232 10 micron
660R
02 use S3232UL 10 micron UL Recognized Hole Pattern Parts List LISTED
ItemPart No Description Case Qty
1 RK21411 White Mounting Head 1 225
2 20707 Oring gasket pack all units 1 57 mm
3 S3232 01 Service Element 12 38 10mm diameter
clearance for fasteners
S3232UL 02 Service Element 12
4 RK30747 01 Seethru Blue Bowl shown 1
RK3047302 02 Metal Bowl NPT plug
White powder paint coating 1 2
5 RK30476 01 Drain Knob shown 1 4
918N6 Steel port plug 38 NPT 1
5 Head top view Fuel ports are
21385 Installation Instructions
3818NPTF Graphs These results are from controlled laboratory tests Field results may vary
100 100 8
75 075 6
Percent 50 PSI 050 4
25 025 2
0 000 0
0 50 100 150 0 30 60 90 0 10 20 30 40 50 60 70
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction Racor Gasoline Solids Capacity Test
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 10 mic element
Marine Gasoline Series Model 3120R
are found on the introduction page
How to Order
3120R RAC 32
Fuel Filter Water Separator Assembly This unit is designed for
gasoline applications and may handle fuel flows up to 120
gallons per hour GPH or 2 gallons per minute The assembly is coated with
a durable applied powder coating that resists corrosion The
spinon filter design is simple to replace and the reusable metal contaminant
collection bowl features a plug for removing unwanted Service Element 12 per case element seals included
Element Part No Micron Rating Element Height Overall Height
S3232UL 10 512 1038 Graphs These results are
from controlled laboratory tests Field results may vary
100 100 8
75 075 6
50 PSI 050
Percent PSI 4
Efficient 25 025 2
0 000 0
0 50 100 150 0 30 60 90 120 0 40 80 120 160
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 3232UL Pattern Parts List The circled number corresponds to the
item number shown below
ItemPart No Description Case Qty
102mm
38 95mm diameter 225
238 clearance for fasteners 57mm
603mm 1 RK3030801 Filter Head with 12 NPT
fuel ports and white powder
paint coating 1
2 2 RK3028801 Mounting Bracket with white
127mm powder paint coating fasteners 1
3 S3232UL Replacement Spinon
Element 120 GPH 10 micron 12
Head top view Fuel
4 4 RK30076 Bowl Oring 20
port orientation is 5 RK3047302 Replacement Metal Bowl
adjustable
5 White powder paint coating 1
Ports are 12NPT
tapered threads 6 918N6 Steel Plug 38 NPT 1
SAEJ476 6
Marine Diesel Spin
on Series Racor Marine Diesel Spinon Series feature a variety of compact
sizes to fit most installations and
cramped engine Heads
These units feature multiple fuel ports and many have more than one inlet or outlet All have a unitized The 200 and 400 Series heads feature a
builtin hand operated fuel priming pump to units feature spinon replaceable filters and contaminant collection bowls except for the All units may
be specified with an inbowl water probe when used with diesel or kerosene Aquabloct filter elements stop water and remove solid A 10 micron filter
secondary and even final is used to filter fuel which is known to be of good quality A 2 micron filter used with
the 120R model or final filter is the finest filtration available and is the last filter used prior to engine ingestion
A simple rule to remember is the finer the filtration the more frequent the filter change Carry extra filters Collection Bowls
The metal bowls used with these models feature an NPT tapered thread plug for removing contaminants An
optional UL Listed shutoff drain valve may be ordered to simplify Available for Diesel fuel systems only
Water Probe RK21069 When used with a Racor Water Detection Module the operator can be alerted of a
highwater condition even while the equipment is operating The bowl is then drained of water at the Note A Racor Water Detection Module is needed to
work with this probe See Probe RK30880 Same features as above except the 12 or 24 vdc electronic detection module is builtin
the probe housing Includes a detachable connector See Accessories Danger Do not use water probes
with gasoline applications This could cause an Along with the information you obtained in SECTION 2 SELECTION page 94 consider the
following Are there any space limitations in the available location The location should provide
adequate space for removing the element draining off contaminants from the bowl and operating
the primer pump on 200 and 400 Series models
2 What filtration rating is needed 2 10 or 30 micron
3 What options are needed Water probe andor a bowl shutoff drain valve
Using this information select a unit from the next page or check the models which follow to
find the right unit for your additional information call your Racor dealer or call Racor customer service at 209 5217860
or 800 3443286 600 AM to 500 PM Pacific Time or email us from our 104
Marine Diesel Spin
on Series
2
110A
120RMAM
200RMAM Series
400MAM Notes
1 Above units feature metal bowls and are approved for diesel service and are UL Listed USCG Accepted
2 Model 110A may be used in pressure applications up to 100 PSI and gasoline service UL Listed
3 The 200RMAM and 400MAM Series units include the head mounted hand priming pump as standard
4 The 4120MAM model features large 34UNF ports for highflow Allow at least 2 inches 51 mm clearance under the units for element replacement and
water For additional information and availability contact customer service 800 3443286 6 AM to 5 PM LISTED
Pacific MODELS 110A 120RMAM 215RMAM 230RMAM 245RMAM 445MAM 460MAM 490MAM GPH 15
35 1 15 15 30 45 45 60 90 120
Flow Rate LPH 57 132 1 57 57 114 170 170 227 341 454
Port Size 14NPT 14NPT 14NPT 14NPT 14NPT 38NPT 38NPT 38NPT 34UNF
Number of Ports 4 4 3 3 3 4 4 4 4
Filter Element R11T R12SUL R15TUL R20TUL R25TUL S3204TUL S3211TUL S3201TUL S3201TUL
Center threads NA M18 X 15 114 114 114 114 114 114 inmm 6152 57145 83211
90229 105267 94239 108275 128324 inmm 3281 3281 4102 4102 4102 45114
45114 45114 45114
Depth inmm 3281 3281 4102 4102 4102 48121 48121 48121 Lbskgs 13059 13059
18080 2090 221 2913 3114 3315 PSI 015 015 012 031 061 017
030 035 045
PressDrop kPa 108 108 083 214 421 120 207 241 PSI 100 7
30 30 30 15 15 15 15
Pressure kPa 689 48 207 207 207 103 103 103 103
Bowl Water
Capacity ml 36 52 58 58 58 58 58 58 Temperature
40 255 F 40 121 C
1 Flow rate for gasoline 105
Marine Diesel Spin
on Series Models are found on the introduction page
Replacement Service Element
110A SERVICE ELEMENT INCLUDES LID SEAL
Basic Model R11T 10 Micron 15 GPH Diesel
35 GPH Gasoline for Primary or Secondary Filtration
Two piece diecast
Consult engine manufacturer or Racor Distributor
aluminum construc
tion
Refer to Diesel Spinon Series introduction page
Mounting Hole Pattern for filter
32 mm
140 mm
516 8 mm diameter
Head Top View clearance for fasteners
Fuel ports are
1418 NPT
SAEJ476 110A
Not to scale Graphs These results are from controlled laboratory tests Field results may vary by 100
20 8
75 15 6
50 PSI 10
Percent PSI 4
Efficient 25 05 2
0 00 0
0 50 100 150 0 3 6 9 12 15 0 5 10 15
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A R11T List The circled number corresponds to the item number shown in the
parts list below
1 ItemPart No Description Case Qty
1 RK21361 110A Head 14NPT Ports 1
2 RK10110 Metal Vent Plug 3824 UNF 1
3 RK21364 110A Housing 1
4 R11T Replacement Element 12
5 RK20022 Metal Plug 1220 UNF 1
RK21363 110A Kit 1
4 21410 Installation 5
Marine Diesel Spin
on Series Model are found on the introduction page
Replacement Service Element
120RMAM SERVICE ELEMENT INCLUDES SEALS
Basic Model R12SUL 2 Micron Recommended
15 GPH for Secondary Final Filtration
Head and bowl are Consult engine manufacturer or Racor Distributor
diecast aluminum
Refer to Diesel Spinon Series introduction page
Mounting Hole Pattern for filter
125
32 mm
142 mm
516 8 mm diameter
Head top view clearance for fasteners
Fuel ports are 120RMAM
1418 NPT
SAEJ476 Not to scale Graphs These results are
from controlled laboratory tests Field results may vary by 100 20
8
75 15 6
Percent 50 PSI 10 4
25 05 2
0 00 0
0 50 100 150 0 3 6 9 12 15 0 10 20 30 40 50
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A R12T List The circled number corresponds to the item number shown in the
parts list below
1 ItemPart No Description Case Qty
1 RK10117 Head 14 NPT Ports 1
2 RK10006 Head Bolt Assembly 1
3 RK10110 Metal Vent Plug 3824 UNF 1
4 R12SUL Replacement Element
2 Micron UL Recognized 20
4 5 RK10012 Bowl Oring 1
6 RK10109 Metal Bowl 1
5 7 RK20022 Metal Plug 1220 UNF 1
8 918N2 Steel Drain Plug 18NPT 1
RK12041 Metal Plug 14 NPT 1
8 RK10063 Kit 1
10218 Installation Instructions 120RMAM
Marine Diesel Spin
on Series Model 215 230 are found on the introduction page
Replacement Service SERVICE ELEMENT INCLUDES SEALS
215RMAM 15 GPH 215 use R15TUL 10 Micron 12case
230RMAM 30 GPH
245RMAM 45 GPH 230 use R20TUL 10 Micron 12case
Includes primer pump 245 use R25TUL 10 Micron 12case
and metal bowl
Refer to Diesel Spinon Series introduction page
Mounting Hole Pattern for filter to scale
516 8 mm
diameter 200
215 51 mm
8 clearance for
203mm fasteners
218mm
245 245RMAM
10 shown
256mm
230RMAM Head top view Fuel ports are
shown 1418 NPT SAEJ476
Graphs These results are from controlled laboratory tests Field results may vary by 100
100 8
215 230 245 215 230 245
75 075 6
Percent 50 All models PSI 050 PSI 4
Efficient 25 025 2
0 000 0
0 50 100 150 0 15 30 45 0 50 100 150 200 250 300 350
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 10 List The circled number corresponds to the item number shown in the parts list
below
ItemPart No Description Case Qty
2 3
1 RK20046 Head 14 NPT Ports 1
1 4 2 RK20025 Primer Pump Assembly 1
3 RK20011 Check Ball and Plastic Cap 1
5 RK20742 Metal Check Ball Cap 1
R15 4 RK10110 Metal Vent Plug 3816 UNF 1
83mm 5 RK12041 Metal Plug 14 NPT 1
400 6 6 See Replacement Service Element box above
102mm
R25 7 RK22244 Bowl Oring 20
550 8 RK22368 Beige Metal Bowl with 38 NPT drain
140mm
7 and 1220 probe ports 1
8 9 RK20022 Metal Plug 1220 UNF 1
10 918N6 Steel Plug 38 NPT 1
10 9 RK20075 Complete Kit 1
22360 Installation Instructions 200 Series
Marine Diesel Spin
on Series Models 445 460 490 are found on the introduction page
How to Order
The example below illustrates how the part numbers are 445MAM P 10
445MAM 45 GPH
460MAM 60 GPH
490MAM 90 GPH
Water Probe 1
Specify P for an
Element Filtration
Rating These units
are standard with a
4120MAM 120 GPH inbowl water probe
The powder coated head Racor part number 10 micron element
includes a hand primer RK21069 Add 10 to the part
pump with 2 inlets outlets number
The metal bowl is standard Omit P if not desired
1 Order a water detection module separately from the Marine Accessories Service Elements
Service elements include seals
445MAM use S3204TUL 10 Micron 12 per case
460MAM use S3211TUL 10 Micron 12 per case
490MAM use S3201TUL 10 Micron 12 per case 490MAM
4120MAM use S3201TUL 10 Micron 12 per case Graphs These results are
from controlled laboratory tests Field results may vary by 100 445 460 490
4120 445 460 4904120
100 8
75 075 6
Percent 50 All models PSI 050 PSI 4
Efficient 25 025 2
0 000 0
0 50 100 150 0 30 60 90 120 0 100 200 300 400 500
Time Minutes Flow GPH Grams
SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
SAE J1839 Water Separation PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 10 Hole Pattern Parts List
The circled number corresponds to the item number shown
38 10 mm diameter 78 ItemPart No Description Case for fasteners 20 mm
1 1 RK22425 Mounting Head 38NPT 1
RK22270 4120 Mounting Head 34UNF 1
2 RK10110 Vent Plug metal 1
225 3 01SP6S Metal Plug 38 NPT 1
57 mm 3
4 S3204TUL 445 Service Element 10 micron 12
445 S3211TUL 460 Service Element 10 micron 12
862219 4 S3201TUL 4904120 Service Element 10 mic 12
460 5 RK30076 Bowl Oring 20
10254 5 6 RK30495 Beige Metal Bowl 14NPT
4904120
12305 12UNF Ports 1
6 7 RK20022 Metal Plug 1220 UNF 1
Head top view 8 RK21069 1 Water Probe 1220 UNF 1
9 RK30880 Water Probe with Electronics 1
8 10 918N4 Steel Plug 14 NPT 1
11 RK19492 UL Listed Marine Shutoff Valve 1
11 10 9 22490 Installation Instructions 400 Series
1 Use with water detection module See Accessories Section
Marine Series MC heavyduty Series MC Marine Fuel
FilterWater Separators protect engines from water dirt foulants
and other contaminants with superb efficiency and filter life The primary 10 or 30 micron fuel filters last by as
much as 1000 hours with average fuel quality
The units are designed for installation on the suction vacuum side of the fuel transfer pump for best Series MC filters are normally installed as
your primary filtration Do not remove the engine secondary
or final filter if one is and Certification for Marine Use
All Racor Series MC units meet 33 CFR Code of Federal Regulations Part 183 subpart J and 46 CFR Part 565075 commercial shipping for diesel fuel
systems Additionally Series
MC units meet or exceed ASTM Specification F120188 which has been adopted by the United
States Coast Guard for inspected vessels The unit label is ASTM formatted for model certification is available upon replaceable cartridge elements
stop water and remove solid contamination and are available
in 2 10 or 30 micron Equipment owners can specify their filtration needs based on application fuel climates and maintenance schedules
A 30 micron filter or primary filter is used to filter raw fuel or poor quality fuel before it can be further filtered
by finer medias such as a 10 or 2 micron
A 10 micron filter or filter is used to filter fuel which is known to be of good quality
A final filter such as a 2 micron filter is the finest filtration available and should be the last filter in the fuel before the fuel is ingested by
the engine
A simple rule to remember is the finer the filtration the more frequent the filter change Carry extra filters with
your Series MC collection sump stores water and contaminants until it is drained by the operator All units
feature a rugged 14 turn drain valve for easy Water Probe Available for Diesel fuel systems only
All units may be ordered with a water probe to alert the operator of a highwater condition even while the
equipment is operating The unit is then drained of water at the earliest The RK30880 Water Probe features builtin electronics to detect the presence
of water An is supplied for in or under dash Along with the information you obtained in SECTION 2 SELECTION page 94 consider the following
Are there any space limitations in the available location The location should provide adequate overhead
space for removing the element and underneath space for draining off What filtration rating is needed 2 10 or 30 micron
3 Is a water probe option needed
4 Can the engine be shut down for servicing
For engines that cannot be shutdown if servicing becomes necessary specify only multiplex valved units
Using this information select a unit from the following page for your additional information call your Racor dealer or call Racor customer service at
209 5217860
or 800 3443286 600 AM to 500 PM Pacific Time or email us from our 110
Marine Diesel Series MC
1
60MC 90MC
180MC 7590MC
75180MC Notes
1 A water probe option is available
2 Allow at least 2 inches 51 mm clearance under the units for draining water
3 Allow at least 5 inches 127mm clearance above the units for element Maximum allowable pressure for all models is 50 PSI 345 kPa
5 These units comply with ASTM Specification F120188 which is accepted by the USCG for inspected vessels
6 For additional information and availability contact customer service at 800 3443286 6 AM to 5 PM Pacific Time
7 Note 75 models do not have the option for both filters to be online at the same BASIC MODELS 60MC 90MC 180MC
7590MC 75180MC 79180MC
Maximum GPH 60 90 180 180 360 540
Flow Rate LPH 227 341 681 681 1363 2044
Port Size NPT 1214 1214 3414 3414 111 12 3414
Service Filter Element 48006 48006 48008 48006 48008 48008
Series Series Series Series Series Series
Height inmm 1875476 1975502 2175552 1975502 2175552 2175552
Width inmm 631160 631160 64163 1725438 175445 25635
Depth inmm 669170 669170 71180 105267 11279 11279
Weight dry Lbskgs 85386 941 144653 2812 41186 60268
Clean Element PSI 040 081 125 151 257 577
Pressure Drop kPa 276 558 861 1041 1772 3978
Operating Temperature 40o 150o F 40o 66o C
Max temperature as tested under ASTMF1201
Marine Diesel Series MC Models 60MC 90MC are found on Series MC introduction page
How to Order
The example below illustrates how the part numbers are constructed
180MC P 2
60MC Water Probe 1 Element
60 GPH 227 LPH Add P for an inunit Filtration Rating
Specify one
90MC water probe
2 for 2 micron
90 GPH 341 LPH 10 for 10 micron
180MC Omit if not desired or
30 for 30 micron
180 GPH 681 Service Elements
12case for all Series MC ELEMENT DOES NOT INCLUDE LID SEALS
Basic Final Secondary Primary
Model Filtration Filtration Filtration
2 micron 10 micron 30 micron 180MC Shown
60 90MC 48006 02 48006 10 48006 30
180MC 48008 02 48008 10 48008 30
A filter is required Hole Pattern Refer to Series MC models introduction page for filter dimensions
Not to scale 60MC90MC
60MC shown 475
180MC
60MC 513
60MC 250 90MC 575 Bracket has clearance for
Port 90MC 300 180MC 750 12 diameter fasteners
centerlines 180MC 450
Fuel Ports 60MC 525 Bracket may be loosened and the unit
90MC 575 may be rotated to suit most 180MC 34NPT 180MC Graphs These
results are from controlled laboratory tests Field results may vary by 100 20
8
48006
75 15 6
48008
Percent 50 PSI 10 4
Efficient 25 05 2
0 00 0
0 50 100 150 0 30 60 90 120 150 180 0 100 200 300 400 500 600
Time Minutes Flow GPH Grams
SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
SAE J1839 Water Separation
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 10 mic Element
Marine Diesel Series MC Models Multiplex
are found on Series MC introduction page
How to Order The example below illustrates how the part numbers are constructed
7590MC P
Basic Model Water Probe Element Filtration
7590MC 1 Duplex unit
180 GPH 681 LPH
75180MC 1 Duplex unit
Specify P for an in
unit water probe
Rating
All units are
equipped with 30
360 GPH 1363 LPH micron filters
Includes detection
79180MC Triplex unit Final filters required
540 GPH 2044 LPH module2 downstream
1 75 models do not have the option for both filters to be on
line at the same time
2 Contact Racor Customer Service for additional information if Service Elements 12case for all Series MC ELEMENT DOES
NOT INCLUDE LID SEALS
Basic Filters Final Secondary Primary
Model used Filtration Filtration Filtration
model 2 micron 10 micron 30 micron 7590MC
Shown
7590MC 2 48006 02 48006 10 48006 30
75180MC 2 48008 02 48008 10 48008 30
79180MC 3 48008 02 48008 10 48008 30
A filter is required Hole Pattern Refer to Series MC introduction page for filter dimensions
Not to scale ItemPart No Description
79180MC
1 quantities are one each
shown 1 180MC Fuel filter water separator
90MC Fuel filter water separator
2 063005 79180MC Main bracket
063002 75180MC Main Bracket
ALL 063000 7590MC Main Bracket
525 3
ALL 3 631013 180MC Clamp bracket assy
1050 631012 90MC Clamp bracket assy
4 063009 79180MC Selector valve
063011 79180MC InletOutlet tube
4 063008 75180MC Selector valve
063007 7590MC Selector valve
Clearance for 38 5 5 061017 Drain valve not shown
diameter fasteners
For parts not listed contact Racor Customer Graphs These results are from controlled laboratory tests Field results may vary
by 100 10 8
180 360
75 8 6 GPH
6 540GPH
Percent PSI 4 PSI 4
Efficient 25 2
0 0 0
0 50 100 150 0 90 180 270 360 450 540 0 300 600 900 1200
Time Minutes Flow GPH Grams
SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
SAE J1839 Water Separation
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 10 mic Element
Marine Diesel Turbine Series Turbine Series Fuel FilterWater Separators
have been protecting engines from water dirt foulants and
other contaminants for over 30 years using a patented threestage process
1 Separation The turbine centrifuge separates solids and free water through centrifugal action
Although the turbine has no moving parts over 30 of the contaminants are removed here
2 Coalescing Smaller water droplets and solids coalesce on the specially designed conical baffle and fall
to the collection bowl
3 Filtration Engines benefit from near 100 water separation and fuel filtration with Racors
proprietary Aquabloct water repelling media
The units are designed for installation on the suction vacuum side of the fuel transfer pump for best may be installed on the pressure side up to 15
Aquabloct replaceable cartridge elements stop water and remove solid contamination and are
available in 2 10 or 30 micron Boat owners can specify their filtration needs based on application fuel climates and maintenance schedules
A 30 micron filter or primary filter is used to filter raw fuel or poor quality fuel before it can be further filtered
by finer medias such as a 10 or 2 micron A 10 micron filter or secondary and even final is used to filter fuel
which is known to be of good quality A 2 micron filter or final filter is the finest filtration available and is the
last filter used prior to engine ingestion
A simple rule to remember is the finer the filtration the more frequent the filter change Carry extra filters Bowls
The seethru bowls used with these models wont discolor from alcohol additives or UV light and feature NPT
tapered thread plug for removing contaminants An optional UL Listed shutoff drain valve may be ordered
to simplify servicing For gasoline or severe service in diesel applications specify metal bowls Available for Diesel fuel systems only
Water Probe RK21069 All units may be ordered with an inbowl water probe to alert the operator of a
highwater condition even while the equipment is operating The bowl is then drained of water at the Note A Racor Water Detection Module is needed to
work with this probe See Probe RK30880 Same features as above except the 12 or 24 vdc electronic detection module is builtin
the probe housing Includes a detachable connector See condition of the filter may be monitored using a vacuum restriction gauge See the Accessories
Along with the information you obtained in SECTION 2 SELECTION page 94 consider the following
Are there any space limitations in the available location The location should provide adequate overhead
space for removing the element and underneath space for draining off contaminants from the bowl
2 What filtration rating is needed 2 10 or 30 micron
3 What options are needed Water probe andor a bowl shutoff drain valve
4 Can the engine be shut down for servicing
For engines that cannot be shutdown if servicing becomes necessary specify only MAV or MAX units
Using this information select a unit from the following page for your additional information call your Racor dealer or call Racor customer service at
209 5217860
or 800 3443286 600 AM to 500 PM Pacific Time or email us from our 114
Marine Turbine Series
2
500MA 500MAM 900MA 1000MA 731000MA 75500MAX
Notes 751000MAX 791000MAV
1 Seethru bowl MA MAX MAV units are approved for Diesel service only UL Listed USCG Accepted
2 Metal bowl MAM MAXM units are approved for Gasoline and Diesel service UL Listed USCG Accepted
3 For additional info and availability contact customer service at 800 3443286 6 AM to 5 PM Pacific
MODELS 500MA 900MA 1000MA 731000MA
75500MAX 75900MAX 751000MAX 771000MA GPH 60 90 180 360 120 180 360
540 540
Flow Rate LPH 227 341 681 1363 454 681 1363 2044 2044
Port Size 3416 12 7814 1 7814 1 3414 3 3416 1 7814 4 7814 4 111 12 3 3414 3
Filter Element 2010 Series 2040 Series 2020 Series 2020 Series 2010 Series 2040 Series 2020 Series 2020 Series 2020
inmm 115292 17432 22559 22559 115292 17432 22559 22559 22559
Width inmm 58147 6152 6152 165419 145368 188476 188476 215546 inmm 48122
7178 7178 12305 95241 11279 11279 12305 Lbskgs 417 627 1045 26118
1777 23104 30136 39177 PSI 025 034 049 17 070 17
37 17 25
Pressure Drop kPa 172 24 34 117 483 117 255 117 172
Max Allowable PSI 15 15 15 15 15 15 15 15 15
Pressure kPa 103 103 103 103 103 103 103 103 103
Bowl ml 110 305 305 610 220 610 610 915 915
Overhead in 4 5 10 10 4 5 10 10 10
Clearance 5 mm 102 127 254 254 102 127 254 254
40 255 F 40 121 C
1 SAEJ1926 Oring boss 2 Effective 11596 call factory for other sizes 3 SAEJ476 NPT National Pipe Tapered thread
4 SAEJ514 JIC Joint Industry Council 37 male flare 5 Required for element removal servicing
Marine Turbine Series Model are found on Turbine Series
introduction page
How to Order
The example below illustrates how the part numbers are 500MA P 10
Basic Model Water Probe 1 Element Filtration
60 GPH Add P for an inbowl Rating
Specify one
Add M for metal bowl water probe 2 for 2 micron
Example 500MAM Omit if not desired 10 for 10 micron
30 for 30 micron 500MA
1 Must be used with Water Detection Kit
See Accessories Service Elements
For all Model 500 Series ELEMENT INCLUDES LID SEAL AND T HANDLE O RING
2010SM OR 2 Micron Brown end caps
Recommended for Final Secondary Filtration
2010TM OR 10 Micron Blue end caps
Recommended for Primary or Secondary Filtration
2010PM OR 30 Micron Red end caps
Recommended for Primary Filtration Only
A filter is required downstream
Hole Patterns
Refer to Turbine Series introduction page for filter dimensions
500MA Standard Fuel Ports 500MAM
3416 UNF with Oring
Boss Seal SAE J1926 525
312 133 mm
540 79 mm
137 mm 360
91 mm
560 638
38 mm
142 mm 162 mm
38 10 mm diameter 38 10 mm diameter
clearance for fasteners clearance for Graphs These results are from controlled
laboratory tests Field results may vary by 100 05 8
75 04 6
Percent 50 PSI 4
02 25 2
0 00 0
0 50 100 150 0 15 30 45 60 0 10 20 30 40 50 60 70
Time Minutes Flow GPH Grams
SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
SAE J1839 Water Separation
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 2010TM Element
Marine Turbine Series Model 500MA
FIGURE 1 500MA Series Cutaway View The circled number corresponds to the item number shown below
Item Part No Description Case Qty
1 RK11888 Thandle 1
11350
RK15078
Thandle Oring
4 3 15005 Lid Gasket 10
4 RK1537701 Body 3416 UNF Ports MA effective 11596 1
RK15082 Body 91618 UNF Ports prior to 11596 1
5 5 RK15090 Mounting Bracket unitized with Bowl Ring MA 1
6 15374 Bowl Gasket supercedes 15009 OringAll models 10
7 RK15013D Turbine Centrifuge Conical Baffle 1
8 RK1527901 Seethru Bowl w Water Probe Plug MA 1
RK1530101 Metal Bowl w14NPT Drain Water Probe Port 1
19 8 9 RK15104 1 Heat Deflector Shield MA 1
10 RK21069 2 Water Probe Assembly 1
18 9 11 RK20022 Metal Water Probe Port Plug 1
12 11340 Drain Fitting Oring New Style 1
13 11041 Bowl Drain Washer New and Old Style 10
500MAP
14 RK19492 Diesel Marine Shutoff Valve Kit 1
Model 11
shown 15 RK15300 Mounting Bracket 3piece MAM 1
16 918N4 Bowl plug 14 NPT Old and New Style 1
17 111910 Bowl Drain Fitting New Style 1
12 RK111910 Complete Bowl Drain Fitting Kit New Style 1
11040 Bowl Drain Fitting Old Style 10
13 18 RK15010B Check Ball w Seal 1
19 RK1508101 3 Phillips Head Capscrews 1024 x 1 4 1
17 16 17 RK15081 3 HexWasher Head Capscrews 1024 x 78 4 1
Old Style4 New Style 20 2010SMOR 2 Micron Element w Seals 12
Drain Fitting 2010TMOR 10 Micron Element w Seals 12
2010PMOR 30 Micron Element w Seals 12
21 RK15079 Return Tube w tapered pipe base threads 1
14 22 RK15211 Seal Service Kit all models not shown 1
15335 Installation Instructions 500MA
1 For replacement only The Coast Guard does not accept FG units
converted to MA 2 For diesel service only Must be used with a Water Detection Kit
3 Models built prior to 296 use RK1508101 after 296 use RK15081
Fuel ports have 1 14 square boss on models made after 296
4 Units built prior to Fall 1998
See Accessories Section
500MAM 3Piece Bracket
Marine Turbine Series Model are found on Turbine Series
introduction page
How to Order
The example below illustrates how the part numbers are 900MA P 10
Basic Model Water Probe Element Filtration
90 GPH Add P for an inbowl Rating
Specify one
Add M for metal bowl water probe 1 2 for 2 micron
Example 900MAM Omit if not desired 10 for 10 micron
30 for 30 micron
1 Must be used with Water Detection Kit
See Accessories Service Elements For all Model 900 ELEMENT INCLUDES LID SEAL AND T
HANDLE O RING
2040SM OR 2 Micron Brown end caps
Recommended for Final Secondary Filtration 900MA
2040TM OR 10 Micron Blue end caps
Recommended for Primary or Secondary Filtration
2040PM OR 30 Micron Red end caps
Recommended for Primary Filtration Only
A filter is required downstream Hole Pattern Refer to Turbine Series introduction page for filter
dimensions
Not to scale
114 mm
Standard Fuel Ports Port 70 mm
7814 UNF with centerline 38 10 mm diameter
Oring Boss Seal clearance for fasteners
SAEJ1926
206 mm Bracket height is adjustable from 2 51 mm
to 550 140 mm above port center Graphs These results are from controlled laboratory tests Field results may vary by application
100 05 8
75 04 6
Percent 50 PSI 02 4
25 2
0 00 0
0 50 100 150 0 30 60 90 0 100 200 300
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 2040TM Element
Marine Turbine Series Model 900MA
FIGURE 1 900MA Series Cutaway View The circled number corresponds to the item number shown below
1 Item Part No Description Case Qty
1 RK11888 Thandle 1
2 11350 Thandle Oring 10
2 RK11005B Lid 1
3 RK11005B02 Lid with Vent Port and Plug Kit not shown 1
3 11007 Squarecut Gasket Lid Bowl ring 10
4 4 2040SMOR 2 Micron Element with Seals 12
2040TMOR 10 Micron Element with Seals 12
5 2040PMOR 30 Micron Element with Seals 12
5 RK19001 Return Tube w tapered pipe bodyend threads 1
6 RK19474 Return Tube w straight bodyend threads 1
6 RK11815101 Body Clamp Bracket 1
7 7 RK19002 Outer Cylinder 1
8 RK111679 Plastic Body Plug 1
8 9 RK11028B Check Ball and Seal 10
10 RK11026D Turbine Centrifuge Conical Baffle 1
3 11 RK21069 1 Water Probe Assembly 1
21 12 RK20022 Metal Water Probe Port Plug 1
20 9 13 RK11341 Bowl Drain Gasket Kit for New and Old Styles 10
11041 Bowl Drain Washer New and Old Style 1
19 10 14 918N4 Bowl Plug 14 NPT New and Old Style 1
15 RK19492 Diesel Marine Shutoff Valve Kit 1
11 16 111910 Bowl Drain Fitting New Style 10
900MAP RK111910 Complete Bowl Drain Fitting Kit New Style
12 11040 Bowl Drain Fitting Old Style 10
17 11340 Drain Fitting Oring New Style 1
18 18 RK11868 2 Heat Deflector Shield MA 1
19 RK1116061 Clear Bowl with Water Probe Port 1
RK11734 Metal Bowl MAM not shown 1
RK1173401 Metal Bowl w 14NPT Drain Water Probe Port 1
17 20 RK11542 HexWasher Head Capscrew 1420 x 1 4 1
13 21 RK11037A Bowl Ring 1
13 22 RK111404 Seal Service Kit all models not shown 1
16 14 16 19466 Installation Instructions 9001000MA
Old Style3 New Style 1 For diesel service only Must be used with a Water Detection Kit
Drain Fitting 2 For replacement only The Coast Guard does not accept FG units
converted to MA 3 Units built prior to Fall 1998
See Accessories Section
Marine Turbine Series Model are found on Turbine Series
introduction page
How to Order
The example below illustrates how the part numbers are 1000MA P 10
Basic Model Water Probe 1 Element Filtration
180 GPH Add P for an inbowl Rating
Specify one
Add M for metal bowl water probe 2 for 2 micron
Example 1000MAM Omit if not desired 10 for 10 micron
30 for 30 micron
1 Must be used with Water Detection Kit
See Accessories Service Elements For all Model 1000 ELEMENT INCLUDES LID SEAL AND T
HANDLE O RING
2020SM OR 2 Micron Brown end caps
Recommended for Final Secondary Filtration
2020TM OR 10 Micron Blue end caps
Recommended for Primary or Secondary Filtration 1000MA
2020PM OR 30 Micron Red end caps
Recommended for Primary Filtration Only
A filter is required downstream
Hole Pattern
Refer to Turbine Series introduction page for filter dimensions
Not to scale
114 mm
Standard Fuel Ports 275
7814 UNF with Oring Port 70 mm
Boss Seal SAEJ1926 centerline
500 127 mm 38 10 mm
810 Bracket height is adjustable diameter
206 mm from 2 51 mm to 1050 clearance for
267 mm above port center fasteners
Graphs These results are from controlled laboratory tests Field results may vary by 100
05 8
75 04 6
Percent 50 PSI 02 PSI 4
Efficient 25 2
0 00 0
0 50 100 150 0 30 60 90 120 150 180 0 100 200 300 400 500 600 700
Time Minutes Flow GPH Grams
SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
SAE J1839 Water Separation PSI X 2 036 inHg PSI X 6895 kPa using SOFTC2A 2020TM Element
Marine Turbine Series Model 1000MA
FIGURE 1 1000MA Series Cutaway View The circled number corresponds to the item number shown below
1 2 Item Part No Description Case Qty
1 RK11888 Thandle 1
3 11350 Thandle Oring 10
2 RK11005B Lid 1
4 RK11005B02 Lid with Vent Port and Plug Kit not shown 1
3 11007 Squarecut Gasket Lid Bowl ring 10
4 RK11815101 Body Clamp Bracket 1
5 5 2020SMOR 2 Micron Element with Seals 12
2020TMOR 10 Micron Element with Seals 12
6 2020PMOR 30 Micron Element with Seals 12
6 RK11008 Return Tube w tapered pipe bodyend threads 1
RK111775 Return Tube w straight bodyend threads 1
7 7 RK11021 Outer Cylinder 1
8 RK111679 Plastic Body Plug 1
9 RK11028B Check Ball and Seal 10
8 10 RK11026D Turbine Centrifuge Conical Baffle 1
11 RK21069 1 Water Probe MA Bowls 1
21 3 12 RK20022 Metal Water Probe Port Plug 1
13 RK11341 Bowl Drain Gasket Kit for New and Old Styles 10
20 9 11041 Bowl Drain Washer New and Old Style 1
19 14 918N4 Bowl Plug 14 NPT New and Old Style 1
15 RK19492 Shutoff Drain Valve Kit for diesel use only 1
16 111910 Bowl Drain Fitting New Style 10
RK111910 Complete Bowl Drain Fitting Kit New Style 1
18 12 11040 Bowl Drain Washer Old Style 10
17 11340 Drain Fitting Oring New Style shown 18 RK11868 2 Heat Deflector
Shield MA 1
19 RK1116061 Clear Bowl with Water Probe Port 1
RK11734 Metal Bowl MAM not shown 1
RK1173401 Metal Bowl w 14NPT Drain Water Probe Port 1
17 20 RK11542 HexWasher Head Capscrew 1420 x 1 4 1
13 13
21 RK11037A Bowl Ring 1
22 RK111404 Seal Service Kit all models not shown 1
16 14 16 19466 Installation Instructions 9001000MA
Old Style3 New Style 1 For diesel service only Must be used with a Water Detection Kit
Drain Fitting 2 For replacement only The Coast Guard does not accept FG units
converted to MA 3 Units built prior to Fall 1998
See Accessories Section
Marine Turbine Series Model are found on Turbine Series introduction
page
How to Order The example below illustrates how the part numbers are 731000MA P
10
Basic Model Water Probe 1 Element Filtration
360 GPH Add P for an inbowl Rating
Specify one
Add M for metal bowl water probe 2 for 2 micron
Example 731000MAM Omit if not desired 10 for 10 micron
30 for 30 micron
1 For use with Water Detection Kit only
See Accessories Service Elements Order two 2 per unit
SERVICE ELEMENT INCLUDES LID SEAL AND T
HANDLE O OR 2 Micron Brown end caps 731000MA
Recommended for Final Secondary OR 10 Micron Blue end caps
Recommended for Primary or Secondary OR 30 Micron Red end caps
Recommended for Primary Filtration Only LISTED
A filter is required Hole Pattern Refer to Turbine Series introduction page for filter to scale
1200 114 mm
175 305 mm
45 mm
OUTLET
INLET
Standard Fuel 250 206 mm 38 10 mm diameter
Inlet Outlet 64 mm clearance for fasteners
3414 Graphs These results are from controlled laboratory tests Field results may vary by 100
20 8
75 15 6
Percent 50 PSI 10 PSI 4
Efficient 25 05 2
0 00 0
0 50 100 150 0 60 120 180 240 300 360 0 250 500 750 1000 1250
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 2020TM Element
Marine Turbine Series Model 1 731000MA Series The circled number corresponds to the
item number shown in the parts list below
1 2 3
Item Part No Description Case Qty
1 1000MA Shell Refer to Model 1000MA
for a complete parts list
2 RK11895 Clamp Bracket 1
4 3 111629 Dual unit Bracket 1
4 11895 Clamp Bracket Assembly 1
5 11923 Outlet Manifold 1
5 6 11072 Elbow Fitting Parker 2507108 1
7 RK19492 UL Listed Marine Drain Valve 1
order two for use with this unit
8 11892 Inlet Manifold 1
111831 Installation Instructions 731000MA
For Water Detection Kits and Manifold Conversion Kits see the
Accessories Section
8 For parts not listed call Racor customer service 800 3443286
6 AM to 5 PM Pacific Time
731000MA
Model shown
Marine Turbine Series Model are found on Turbine Series introduction
page
How to Order The example below illustrates how the part numbers are constructed
75500MAX P 10
Basic Model Water Probe 1 Element Filtration
120 GPH Add P for an inbowl Rating
Add M for metal bowl Specify one
water probe 2 for 2 micron
Example 75500MAXM 10 for 10 micron
Note All standard bowls
Omit if not desired
include probe port plug 30 for 30 micron
1 Must be used with Water Detection Kit only
See Accessories Section
Service Elements
Order two 2 per unit
SERVICE ELEMENT INCLUDES LID SEAL AND T HANDLE O RING
2010SM OR 2 Micron Brown end caps
Recommended for Final Secondary Filtration
2010TM OR 10 Micron Blue end caps
Recommended for Primary or Secondary Filtration
2010PM OR 30 Micron Red end caps LISTED
Recommended for Primary Filtration Only
A filter is required Hole Pattern Refer to Turbine Series introduction page for filter
634
500 161 mm
127 mm
38 10 mm diameter
510 clearance for fasteners
130 mm
1268
322 mm
Inlet Outlet
on valve underside
Not to scale 3416UNF Graphs These results are from controlled laboratory tests Field results may vary by
100 20 8
75 15 6
50 PSI 10
Percent PSI 4
Efficient 25 05 2
0 00 0
0 50 100 150 0 30 60 90 120 0 20 40 60 80 100 120 140
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 2010TM Element
Marine Turbine Series Model 1 75500MAX Series The circled number corresponds to the
item number shown in the parts list below
1 2 3
Item Part No Description Case Qty
1 500MA Shell Refer to Model 500MA
for a complete parts list
2 RK15329 Main Bracket will not accommodate
piece body clamp brackets 1
3 RK19476 Gauge Assembly 1
4 RK15378 Body Clamp Bracket OnePiece 1
5 RK15300 Body Clamp Bracket ThreePiece
See illustration below 1
5 RK15344 Rigid Tubing Assembly 1
6 RK15321 Valve Assembly 1
6 4
RK15389 Valve Service Kit 1
7 RK19492 UL Listed Marine Drain Valve
7 order two for use with this unit 1
15350 Installation Instructions 75500MAX
RK15300 Threepiece bracket
For Fuel Port Adapter Fittings Water Detection Kits and Manifold
75500MAX
Model shown Conversion Kits see the Accessories Section
For parts not listed call Racor customer service 800 125
Marine Turbine Series Model are found on Turbine Series introduction
page
How to Order The example below illustrates how the part numbers are constructed
75900MAX P 10
Basic Model Water Probe 1 Element Filtration
180 GPH Add P for an inbowl Rating
Specify one
Add M for metal bowl water probe 2 for 2 micron
Example 75900MAXM Omit if not desired 10 for 10 micron
30 for 30 micron
1 Must be used with Water Detection Kit only
See Accessories Section
Service Elements
Order two 2 per unit
SERVICE ELEMENT INCLUDES LID SEAL AND T HANDLE O RING
2040SM OR 2 Micron Brown end caps
Recommended for Final Secondary Filtration
2040TM OR 10 Micron Blue end caps
Recommended for Primary or Secondary Filtration
2040PM OR 30 Micron Red end caps LISTED
Recommended for Primary Filtration Only
A filter is required Hole Pattern Refer to Turbine Series introduction page for filter dimensions
1763
Not to scale 448 mm
89 mm
38 10 mm diameter
clearance for fasteners
1100
279 mm NOTE The Inlet Outlet Port Male Fittings are
7814UNF threads with 37 Flare JIC
SAEJ514 These permanent fittings must not
be removed Damage to the valve may result
Inlet Outlet See fittings selection chart in Accessories Section
On valve underside to adapt to your fuel system piping See Note at Graphs
These results are from controlled laboratory tests Filter results may vary by 100
20 8
75 15 6
50 PSI 10
Percent PSI 4
Efficient 25 05 2
0 00 0
0 50 100 150 0 60 120 180 0 100 200 300 400 500 600
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 2040TM Element
Marine Turbine Series Model 1 75900MAX Series The circled number corresponds to the item
number shown in the parts list below
1 2 3
Item Part No Description Case Qty
1 900MA Shell Refer to Model 900MA
for a complete parts list
2 RK19476 Gauge Assembly 1
3 RK19486 Dual unit Bracket 1
4 RK19475 Rigid Tubing Assembly 1
5 RK19492 UL Listed Marine Drain Valve
order two for use with this unit 1
6 RK19473 Valve Assembly 1
RK19506 Valve Service Kit 1
19485 Installation Instructions 75900MAX
6 5
For Fuel Port Adapter Fittings Water Detection Kits and Manifold
Conversion Kits see the Accessories Section
75900MAX Model shown
For parts not listed call Racor customer service 800 3443286
6 AM to 5 PM Pacific Time
Marine Turbine Series Model are found on Turbine Series introduction
page
How to Order The example below illustrates how the part numbers are constructed
751000MAX P 10
Basic Model Water Probe 1 Element Filtration
360 GPH Add P for an inbowl Rating
Specify one
Add M for metal bowl water probe 2 for 2 micron
Example 751000MAXM Omit if not desired 10 for 10 micron
30 for 30 micron
1 Must be used with Water Detection Kit only
See Accessories Service Elements Order two 2 per unit ELEMENT INCLUDES LID SEAL AND T
HANDLE O RING
2020SM OR 2 Micron Brown end caps
Recommended for Final Secondary Filtration
2020TM OR 10 Micron Blue end caps
Recommended for Primary or Secondary Filtration
2020PM OR 30 Micron Red end caps LISTED
Recommended for Primary Filtration Only
A filter is required Hole Pattern Refer to Turbine Series introduction page for filter dimensions
Not to scale 775 1763
279 mm 448 mm
98 mm
38 10 mm diameter
clearance for fasteners
1050 NOTE The Inlet Outlet Port Male Fittings are
267 mm 7814UNF threads with 37 Flare JIC
SAEJ514 These permanent fittings must not
be removed Damage to the valve may result
Inlet Outlet See fittings selection chart in Accessories Section
On valve underside to adapt to your fuel system piping See Note at Graphs
These results are from controlled laboratory tests Field results may vary by 100
5 8
75 4 6
Percent PSI 2 PSI 4
Efficient 25 2
0 0 0
0 50 100 150 0 60 120 180 240 300 360 0 300 600 900 1200
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 2020TM Element
Marine Turbine Series Model 1 751000MAX Series The circled number corresponds to the item
number shown in the parts list below
1 2 3
Item Part No Description Case Qty
1 1000MA Shell Refer to Model 1000MA
for a complete parts list
2 RK19476 Gauge Assembly 1
3 RK111777 Dual unit Bracket 1
4 RK19475 Rigid Tubing Assembly 1
5 RK19492 UL Listed Marine Drain Valve
order two for use with this unit 1
6 RK19473 Valve Assembly 1
4 RK19506 Valve Service Kit 1
19485 Installation Instructions 751000MAX
6 For Fuel Port Adapter Fittings Water Detection Kits and Manifold
5 Conversion Kits see the Accessories Section
For parts not listed call Racor customer service 800 3443286
751000MAX Model shown
6 AM to 5 PM Pacific Time
Marine Turbine Series Model are found on Turbine Series introduction
page
How to Order The example below illustrates how the part numbers are constructed
771000MA P 10
Basic Model Water Probe 1 Element Filtration
540 GPH Add P for an inbowl Rating
Specify one
Add M for metal bowl water probe 2 for 2 micron
Example 771000MAM Omit if not desired 10 for 10 micron
30 for 30 micron
1 Must be used with Water Detection Kit only
See Accessories Service Elements Order three 3 per unit ELEMENT INCLUDES LID SEAL AND
HANDLE O RING
2020SM OR 2 Micron Brown end caps
Recommended for Final Secondary Filtration
2020TM OR 10 Micron Blue end caps
Recommended for Primary or Secondary Filtration
2020PM OR 30 Micron Red end caps LISTED
Recommended for Primary Filtration Only
A filter is required Hole Pattern Refer to Turbine Series introduction page for filter dimensions
Not to scale
1275 38
324 mm 10 mm
175 diameter
45 mm clearance
fasteners
OUTLET
INLET 810 594
206 mm 151 mm
250 1775
Inlet Outlet 64 mm 451 mm
111 12 Graphs These results are from controlled laboratory tests Field results may vary by 100
20 8
75 15 6
50 PSI 10
Percent PSI 4
Efficient 25 05 2
0 00 0
0 50 100 150 0 90 180 270 360 450 540 0 500 1000 1500 2000
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 2020TM Element
Marine Turbine Series Model 1 771000MA Series The circled number corresponds to the item
number shown in the parts list below
1 2 3 4
Item Part No Description Case Qty
1 1000MA Shell Refer to Model 1000MA
for a complete parts list
2 111632 Triple unit Bracket 1
3 11895 Clamp Bracket Assembly 1
4 RK11895 Clamp Bracket 1
5 5 11902 Outlet Manifold 1
6 11072 Elbow Fitting Parker 2507108 1
7 RK19492 UL Listed Marine Drain Valve
6 order three for use with this unit 1
8 11893 Inlet Manifold 1
111831 Installation Instructions 771000MA
For Water Detection Kits and Manifold Conversion Kits see the
Accessories Section
For parts not listed call Racor customer service 800 3443286
8 7
6 AM to 5 PM Pacific Time
771000MA Model shown
Marine Turbine Series Model are found on Turbine Series introduction
page
How to Order The example below illustrates how the part numbers are constructed
791000MAV P 10
Basic Model Water Probe 1 Element Filtration
540 GPH Add P for an inbowl Rating
Specify one
Add M for metal bowl water probe 2 for 2 micron
Example 791000MAVM Omit if not desired 10 for 10 micron
30 for 30 micron
1 For use with Water Detection Kit only
See Accessories Service Elements
Order three 3 per unit ELEMENT INCLUDES LID SEAL AND T HANDLE O OR 2 Micron Brown end caps
Recommended for Final Secondary OR 10 Micron Blue end caps
Recommended for Primary or Secondary OR 30 Micron Red end caps
LISTED
Recommended for Primary Filtration Only
A filter is required Hole Pattern Refer to Turbine Series introduction page for filter
38
1275 10 mm
OUTLET
324 mm diameter
INLET clearance
550 for
140 mm fasteners
800 151 mm
203 mm 1775
451 mm
Inlet Outlet
3414 NPT Not to Graphs These results are from controlled
laboratory tests Field results may vary by 100 3
75 6
Percent 50 PSI 4
Efficient 1
25 2
0 0 0
0 50 100 150 0 90 180 270 360 450 540 0 300 600 900 1200
Time Minutes Flow GPH Grams
SAE J1839 Water Separation SAE J905 Fuel Flow Restriction SAE J905 Solids Capacity
PSI X 2036 inHg PSI X 6895 kPa using SOFTC2A 2020TM Element
Marine Turbine Series Model 1 791000MAV Series The circled number corresponds to the item
number shown in the parts list below
1 2 3 Item Part No Description Case Qty
1 1000MA Shell Refer to Model 1000MA
for a complete parts list
2 111632 Triple unit Bracket 1
3 11895 Clamp Bracket 1
5 4 111761 U Bracket 1
5 19461 Outlet Manifold 1
6 RK11073 12 Ball Valve 1
9 6 7 111626 Formed Tubing Assembly 1
8 RK19492 UL Listed Marine Drain Valve
order three for use with this unit 1
9 19460 Inlet Manifold 1
111821 Installation Instructions 791000MAV
For Water Detection Kits and Manifold Conversion Kits see the
Accessories Section
For parts not listed call Racor customer service 800 3443286
6 AM to 5 PM Pacific Time
791000MAV Model shown
Marine Hydraulic Fluid Filters Racor Marine Hydraulic Fluid Filters feature low and
high pressure models in a variety of compact sizes
and capabilities to fit most installations and systems
Low Pressure Spin
On Filters 175 PSI
These Racor water absorbing filters feature a specially designed media that traps solid contaminants like dirt
and rust and damaging water As the element fills with water and plugging occurs flow slows and the head
goes into a bypass mode Water absorbing spinon hydraulic fluid filters are available in a 10 micron applications include return line filtration and
other low pressure under 175 PSI fluid Pressure Filter Heads
To make monitoring of the element easy Racor offers a range of heads with pressure restriction large diameter heads with standard color coded bar
Pressure Cartridge Type Filters 3000 PSI
Racor hydraulic filters for medium pressure applications are rated to 3000 PSI and are crafted from anodized aluminum An optional popup indicator
signals the bypass condition and need for however a builtin bypass valve allows the system to continue operating in an flow rates and housing
lengths accept a 10 micron element with extended lengths providing life and larger sump applications include all medium pressure system circuits
under 3000 Breather Filter
A reservoir breather filter provides precision hydraulic components with special protection against and destructive moisture The use of a reservoir
breather filter is especially critical in high or where moisture is present near hydraulic systems Racors filter contains a ten micron
media which removes both dirt and moisture from hydraulic reservoir air The spinon design provides ease
of service Adapters are available to fit most Identify the hydraulic fluid circuit system pressure
Under 175 PSI Use a Racor lowpressure spinon filter with a stationary head
Under 3000 PSI Use a Racor model
2 Are there any space limitations in the available location The location should provide adequate
space for removing the element
For a Reservoir Breather refer to the selection table in the applicable page that this information select a unit from the next page or check the
pages which follow to
find the right unit for your additional information call your Racor dealer or call Racor customer service at 209 5217860
or 800 3443286 600 AM to 500 PM Pacific Time or email us from our 134
Marine Hydraulic Fluid Filters
2
RAC3510 HP60077
HP60083
RAC5710
HP60080
RAC51110
HP60086
LOW PRESSURE SERIES HIGH PRESSURE Notes
1 Racor low pressure filters fit most standard filter heads in service See available heads from Racor on the following pages
2 Allow 2 inches of free space below each unit for element removal
3 For additional information and availability contact customer service 800 3443286 6 AM to 5 PM Pacific BASIC MODELS RAC3510 RAC5710
RAC51110 HP60077 HP60080 HP60083 HP60086
Maximum GPH 900 3000 3000 1200 1200 3000 3000
Flow Rate LPH 3407 11355 11355 4542 4542 11355 11355
Filter Element Cellulose RAC3510 RAC5710 RAC51110 FC60078 FC60081 FC60084 FC60087
Cartridge Microglass NA NA NA FC60079 FC60082 FC60085 FC60088
Center Threads 112 1 1216 1 1216 NA NA NA NA
Head Port Size 1 NA NA NA 1 11612UN 1 11612UN 1 51612UN 1 51612UN
Bypass Setting PSI NA NA NA 25 25 25 25
Width Diameter inmm 37094 500127 500127 400102 400102 450114 450114
Height inmm 550140 700178 1100280 77195 114291 10254 143363
Weight Lbskgs 1306 2310 314 3516 4621 6429 8739
Clean Pressure PSI 25 25 17 22 20 25 25
Drop MaxFlow bar 17 17 12 15 14 17 17
Maximum Allowable PSI 175 175 175 3000 3000 3000 3000
Working Pressure bar 12 12 12 206 206 206 206
Typical Beta Rating
220 Cellulose uM 1018 1018 1018 814 616 412 617
220 Microglass uM NA NA NA 25 26 26 37
Operating Temperature 40 225 F 40 107 C
1 SAE Oring Boss Type SAE J1926
Marine Hydraulic Fluid Filters Low are found on Hydraulic Fluid
Filters introduction page
How to Order The example below illustrates how the part numbers are RAC57 10
Maximum Pressure 175 PSI121 bar Nominal Mounting Head Selection
RAC35 900 GPH 3407 LPH
Micron See the table below
37 diameter x 55 long
RAC57 3000 GPH 11355 LPH Rating RAC35 Use type 1
5 diameter x 7 long Specify RAC57 Use type 2
RAC511 3000 GPH 11355 LPH
5 diameter x 11 long 10 only RAC5111 Use type Service Elements
Service elements include seal
Service Micron Solids Capacity Case RAC51110
Element No Rating Water Dirt Quantity shown
RAC3510 10 221ml 122 grams 12
RAC5710 10 842ml 47 grams 6
RAC51110 10 842ml 47 grams 6
Hydraulic Mounting Head
1 12
Type 1 Type 2 Type 2 38mm
07500 Series 12500 L or R Series 12500MP Series
IN HH12515L Shown Multiport head IN HG15LF Gauge
Not to scale
Part Number Head Port Center By pass Filter Case
Type Sizes Thread Setting PSID Application Quantity
Maximum flow rate for the heads below is 15 GPM 900 GPH and up to 175 PSI 121 bar
IN HH 07503 1 34NPT 112 UN 3 Use with 1
IN HH 07515 1 34NPT 112 UN 15 3510 1
IN HH 07525 1 34NPT 112 UN 25 filter 1
Maximum flow rate for the heads below is 50 GPM 3000 GPH and up to 175 PSI 121 bar
IN HH 12515 1 2 1 14NPT 1 1216 UN 15 Use with 1
IN HH 12525 1 2 1 14NPT 1 1216 UN 25 5710 1
IN HH 12515MP 2 2 1 14NPT 1 1216 UN 15 51110 1
IN HH 12525MP 2 2 1 14NPT 1 1216 UN 25 filters 1
1 Specify L or R L provides the standard colorcoded bar restriction gauge on the side of the head with the
flow direction going to your left R has the flow going to the right See center head illustration above
2 MP signifies a multiport head The multiports are for an optional inhead gauge such as the IN HG15LF
liquid filled 15 diameter compound gauge 18NPT See right illustration above
Marine Hydraulic Fluid Filters High are found on Hydraulic Fluid Filters
introduction page
How to Order The example below illustrates how the part numbers are HP60086 C
Maximum Pressure 3000 PSI206 bar
HP60077 1200 GPH 4542 LPH
Filter Element Media Specify one
C for Cellulose or
HP60080 1200 GPH 4542 LPH
HP60083 3000 GPH 11355 LPH M for Microglass
HP60086 3000 GPH 11355 Service Elements
Service elements include seal
Model No Service Micron Beta Rating Case
Element No Rating Typical 220 Quantity
HP60077C FC60078 10 8 14 6
HP60077M FC60079 10 25 6
HP60080C FC60081 10 6 16 6 HP60086
HP60080M FC60082 10 26 6 Shown
HP60083C FC60084 10 4 12 6
HP60083M FC60085 10 26 6
HP60086C FC60087 10 6 17 6
HP60086M FC60088 10 37 6
Reservoir Breather Adapters
Breather Center Breather Breather Recommended Case
Part Number Threads Diameter Length Adapters Qty
See below
RAC35RB 112UN 300 500 IN RBA60076 12
IN RBA3416
Replaces existing
Length 112 filler cap
INRBA3416 End View
This adapter replaces
Diameter the existing breather
cap or fill cap
T1 T2
IN RBA60076
Adapter Thread Thread Adapter Adapter Case
Part Number T1 T2 Diameter Length Qty
IN RBA60076 112UN 34NPT 105 263 1 Typical
mounted on side or
IN HRBA3416 112UN Tank Cap 326 127 1 top of reservoir
Marine Liquid Transfer System SYSTEM
Top view
Inlet wands
Outlet 3411 12NH
Side view
Special Notes
1 WARNING Explosion hazard Do not pump flammable fluids such as gasoline alcohol solvents etc
2 The 14 HP 115 VAC motor is Underwriters Laboratories Recognized and CSA Listed
3 For additional information and availability contact customer service at 800 3443286
6 AM to 5 PM Pacific BASIC MODEL GLT60006
Recommended Fluids Petroleum based and Water emulsions
Filter Elements 74W 40W 25W 20C 10C 10B 03B WR
Maximum Flow Rate
Gallons per minute GPM 4
Liters per minute LPM 15
Maximum PSI 50
Pressure allowable bar 35
Port Thread Inlet Outlet 1214 NPTF
Hose Connection Thread 3411 12 NH
Height in 850
mm 216
Width in 775
mm 197
Length in 1575
mm 400
Weight dry lbs 24
kgs 11
Operating Temperature 15o 120o F 26o 49o C
Marine Liquid Transfer System Model are found on Liquid Transfer System introduction
page
How to Order The Racor Guardian Liquid Transfer System can be ordered with a
broad selection of options The example below illustrates how the part numbers GLT 60006
Basic Model Element Filtration Media
240 GPH Includes visual 60006 10 Micron Cellulose is
differential indicator hoses Standard For other medias
and wands Note All seals order from Replacement
are of Viton rubber Service Elements block below
Viton is a registered trademark of Service Elements The element end cap cover
ring is reusable and is NOT included with service elements
Part number Media Description Case Qty
ING60000 74W 74 Micron Wire Mesh 1
ING60002 40W 40 Micron Wire Mesh 1
ING60001 25W 25 Micron Wire Mesh 1
ING60010 20C 20 Micron Cellulose 2 The 14 HP 115 VAC
motor is Underwriters
ING60006 10C 10 Micron Cellulose 2 Laboratories Recognized
ING60007 10B 10 Micron Microglass 2 CSA Listed and features
replaceable brushes
ING60008 03B 3 Micron Microglass 2
ING60009 WR Water Removing Media water capacity
is 15 fluid ounces 2
For optional extended length elements see parts list on next page
Flow vs Viscosity Performance
Note Do not use unit with fluid viscosities greater than 16000 SUS
16000
The more viscous thicker
14000 the fluid the lower the flow
12000
rate
In the event of bypass
10000 the fluid goes into a
Viscosity continuous loop within the
8000
pump and does not leave
6000 the unit This ensures
4000 100 filtration even when
unattended No unfiltered
2000
fluid reaches downstream
0 components
0 60 120 180 240
Flow in Gallons per Hour GPH
Marine Liquid Transfer System Model 1 GLT View The circled numbers correspond to the item numbers
shown in the parts list below
8 10
3 4
9 11 6 7
No Description Case Qty ItemPart No Description Case Qty
1 ING60014 End Cap for element 1 SERVICE PARTS
2 ING60026 End Cap Oring Viton 1 6 ING60035 115 VAC Motor Assembly 1
7 ING60036 Inlet Screen 1
STANDARD ELEMENTS 8 ING60020 18 Wand Crevice Assembly 1
3 ING60000 74W 74 micron Woven wire 1 9 ING60021 18 Wand Adapter Assembly 1
ING60002 40W 40 micron Woven wire 1 10 ING60004 63 Inlet Hose Assembly 1
ING60001 25W 25 micron Woven wire 1 11 ING60005 63 Outlet Hose Assembly 1
ING60010 20C 20 micron Cellulose 2 12 ING60023 Quick Disconnect Kit 2
ING60006 10C 10 micron Cellulose 2 13 ING60019 Hose Gasket Viton 1
ING60007 10B 10 micron Microglass 2
ING60008 03B 3 micron Microglass 2 PUMP SERVICE PARTS Not shown
ING60009 WR Water Removing 2 14 ING60013 Gerotor Set 1
15 ING60015 Shadow Plate 1
EXTENDED LENGTH ELEMENTS 16 ING60016 Outlet Plate 1
4 ING60027 40W 40 micron Woven wire 1 17 ING60017 Gerotor Ring 1
ING60028 40SA 40 micron Synthetic 1 18 ING60018 PolyPak Seal 1
ING60029 25W 25 micron Woven wire 1
ING60030 20C 20 micron Cellulose 1
ING60031 10B 10 micron Microglass 1
INHP60087 10C 10 micron Cellulose 1
ING60033 03B 3 micron Microglass 1
ING60034 03C 3 micron Cellulose 1
5 ING60022 Element Extension Tube 1
Marine Fuel Air Separators LG50
GASOLINE Model LG50 The fill flow rate capacity is 12 cubic feet air per minute 90 GPM and can handle most
commercial fuel dispensing nozzles The vent line connections are for standard 58 ID rubber hose
2 DIESEL OR GASOLINE FUEL Model LG100 The fill flow rate capacity is 17 cubic feet air per minute 127 GPM
and handles commercial fuel dispensing nozzles The vent line connections are for standard 58 ID rubber Notes
1 Exercise caution to avoid fuel splash if fueling nozzle is not equipped with automatic shutoff capability
Wrap an absorbant cloth around fill portnozzle to ensure no spillage
2 Order Adapter Kit No RK50033 12NPTF fittings to accommodate all other vent line hose sizes
3 UL Listing pending meets USCG pleasure craft For additional information and availability contact customer service at 800 3443286 6 AM to 5 PM
Pacific BASIC MODELS LG50 LG100
Fuel type Gasoline Maximum Flow Capacity
Cubic feet air per minute CFM 12 17
Gallons per minute GPM 90 127
Liters per minute LPM 341 481
Hose fitting size ID 58 58
Optional adapter RK50033 12NPTF 12NPTF
Height in 6 9 34
mm 1524 2477
Diameter in 1 34 4
mm 445 1016
Weight dry lbs 12 162
kgs 054 073
Operating Temperature 40o 255o F 40o 121o C
Marine Fuel Air Separators Models LG50 are found on Fuel Air Separator introduction page
LG50 LG100 FEATURES
LG50 12 CFM Gasoline Meets USCG pleasure craft LG100 17 CFM Gasoline Allows fuel tank topoff without overboard
spillage
Diesel Applications Prevents overboard spillage due to agitation
Each unit includes standard Saves fuel costs and prevents possible fines
58 male hose barbs hose Contains thermal expansion up to 24 PSI
clamps and instructions Prevents maintenance due to fuel stains on vessel
LG50
How the Lifeguard Works LG100
LG100 1 In the First Stage the
LG50 1 In the First Stage the UP To vent venting tank fuel is deflected by
venting tank fuel is diffused by the the Flow Diverter Fuel is directed
Flow Diverter Air is allowed to down to the drain ports and air is
bypass the diverter but fuel is allowed to bypass and continue
3 traveling up
directed back to the tank
2 The Second Stage defoams
2 In the Second Stage vapor 1 the fuel through a fine wire mesh
screen which filters out large
collects on the interior surfaces 2 contaminants Under the screen
and coalesces The fuel returns the fuel collects temporarily until
downward by gravity and air
continues up and out of the unit
1 it can flow back down to the fuel
tank
3 In the Third Stage vapor
The Safety Relief Valve includes collects on the interior surfaces
a floating check ball which will not and coalesces The fuel returns
permit a large inrush of fuel to 2 downward by gravity and air
bypass In the event of internal continues up and out of the unit
The Safety Relief Valve includes
pressure reaching 24 PSI the a floating check ball which will not
spring will compress and open permit a large inrush of fuel to
the safety seat bypass In the event of internal
Cutaway views pressure reaching 24 PSI the
spring will compress and open
are not to scale From fuel tank the safety Information
The LG50 has no serviceable parts See the Parts List below for fitting Part No Description Qty
RK50021 LG100 Replacement screen spring check ball seals 1
RK50023 LG100 2piece Steel Mounting Bracket not shown 1
Note Use only one elbow fitting with each unit
RK50033 Straight Fitting Adapter 12 NPT female not shown 1 as fitting orientation is random Two elbow
RK50003 Elbow Fitting 58 hose barb see view at right 1 fittings may not point to the directions you wish
INSPECT FUEL SYSTEM COMPONENTS AND THE OVERBOARD VENT OF OBSTRUCTIONS ANNUALLY
These units must be installed vertically or up to 60 from vertical in the vent line with the arrow pointing UP towards vent
Do not allow loops or low spots where fuel may pool Flying insects may build nests in vent ports which may also
obstruct the escaping vapors These situations may be evident by premature tripping of the fuel nozzle automatic
shutoff during refueling or constant fuel filling splashups
In the event of severe fuel tank biological the units may be fouled and require inspection or cleaning
To disassemble simply unthread the fittings from the housing and clean only in a fresh solvent bath Coat the seals
with motor oil and reassemble the unit in reverse order
Marine Drinking Water Filters WFA12S5 S30 S60
The Sediment Removal units can handle up to 6 GPM 125 PSI and are available in 5 30 and 60 micron filter
ratings
Five 5 micron elements trap fine particles sixty 60 micron elements trap larger particles but have a longer life
2 The Taste and Odor Removal unit can handle up to 3 GPM 125 PSI and is rated at 5 Notes
1 Sediment filters S60 remove rust sand algae and other suspended solids
2 The Taste and Odor filter WFA12T5 removes rust sand algae suspended solids and also
features an activated carbon core to remove contaminants which cause undesirable taste and odor
3 Both units above feature the same housing Only the filter element and unit label are different
4 These units are for cold drinking water filtration and are not intended to be used with hot water
sea salt water unsafe water or water of unknown quality
5 For additional information and availability contact customer service at 800 3443286 6 AM to 5 PM Pacific BASIC MODELS
WFA12 S5S30S60 WFA12 T5
Fluid Filtered Drinking water Drinking water
Filter Element WFCS5 S30 S60 WFCT5
Maximum Flow Capacity
Gallons per minute GPM 6 3
Liters per minute LPM 23 12
Maximum Pressure PSI 125 125
Port Size Inlet Outlet 3414 NPTF 3414 NPTF
Height in 1250 1250
mm 318 318
Diameter in 525 525
mm 1334 1334
Weight dry lbs 31 31
kgs 14 14
Operating Temperature cold water only 33o 100o F 06o 38o C
Marine Drinking Water Filters Model are found on Drinking Water Filter
Series introduction page
How to Order The example below illustrates how the part numbers are WFA12 S30
For cold water filtration only WFA12 is
the basic model and includes mounting
Filtration Removal Type Rating
Specify one
T5 for 5 Micron Taste Odor
head cartridge and transparent sump
S5 for 5 Micron Sediment
Flow Rates with T5 element 3 GPM S30 for 30 Micron Sediment
180GPH all others 6 GPM360 GPH S60 for 60 Micron Cartridges
Service cartridges DO NOT include head seal
WFC T5 5 Micron Taste and Odor Removal Cartridge
WFC S5 5 Micron Sediment Removal Cartridge WFA12T5
WFC S30 30 Micron Sediment Removal Cartridge WFA12S5
WFA12S30
WFC S60 60 Micron Sediment Removal Cartridge Hole Pattern
Refer to Drinking Water Filters introduction page for filter Head Ports are
3414 NPTF
38 95 mm diameter
225 clearance for fasteners
1150 292 mm 57 mm
Port center lines
to bottom
Note Allow 2 51 mm NOTE The Water Filter may be supported by
below the unit for servicing rigid pipe or tubing Use the above dimensions
if using the optional mounting bracket
Not to scale
Parts List The circled number corresponds to the item number shown in the parts list below
Filter design prior ItemPart No Description Case Qty
to June 1 1998 1 WFH12 Water Filter HeadSump new design 6
1 2 WF037 HeadSump Seal new design 1
3 WFCT5 5 Micron Taste and Odor Cartridge 20
7 2 Maximum flow rate is 3 GPM 180 GPH
WFCS5 5 Micron Sediment Cartridge 20
3 4 Maximum flow rate is 6 GPM 360 GPH
WFCS30 30 Micron Sediment Cartridge 20
3 Maximum flow rate is 6 GPM 360 GPH
WFCS60 60 Micron Sediment Cartridge 20
Maximum flow rate is 6 GPM 360 GPH
4 WF035 Optional Mounting Bracket Kit 1
5 WF039 Optional Bowl Wrench new design 1
5 6 WF010 Optional Bowl Wrench old design 1
6 7 WF009 HeadSump Seal old design 1
For parts not listed call Racor customer service PT
Marine Air Filtration Air AF M408512
AF M501012 AF Notes
1 For additional information and availability contact customer service at 800 3443286 6 AM to 5 PM Pacific BASIC MODELS AF
M408512 AF M501012 AF M601212
Max Air Flow CFM 800 1200 1600
Ls 3776 5664 7552
Outlet Diameter in 400 500 600
mm 1016 1270 1524
Filter Element AF M8040 AF M8050 AF M8060
Length in 1250 1250 1250
mm 3175 3175 3175
Depth in 959 1114 1351
mm 2435 2828 3432
Hose Barb size in 100 125 125
mm 254 254 3175
Weight dry Lbs 416 503 800
kgs 189 228 363
Operating Temperature 40o 240o F 40o 116o C
Values given are cubic feet per minute CFM and liters per second Ls
Marine Air Filtration Marine Air are found on the Introduction page
4 clearance min
AF M408512 50
needed for element removal
Element AF M8040
335 Mounting
851mm bracket
1250
335 3175mm
851mm
959
1270mm
838mm
holes
10 1270mm
254mm 1 hose
Top View Front View barb
No Scale Mounting Bracket
AF M501012 50
4 clearance min
needed for element removal
Element AF M8050
Mounting
bracket
851mm
1250
335 3175mm
851mm
1114
033 838mm
holes
10 1270mm
125 hose
254mm
barb
Top View Mounting Bracket Front View
No Scale
AF M601212 15
4 clearance min
needed for element removal
Element AF M8060
600 Mounting
1524mm bracket
1250
3175mm
1524mm
1351
1246mm
104mm
holes 600
75 1524mm
125 hose
191mm
barb
No Scale Top View Mounting Bracket Front View
Marine Accessories hose for gasoline
diesel lube oil and hydraulic systems for commercial and recreational to Order
CGH
5
Number Hose ID size
USCG Standard length is
5 14
Accepted 6 516 a 350 foot roll
Hose 8 1316 Specify 50 for a
10 12 50 foot roll
12 58
16 kg
InHg
Part Working Burst Minimum
Number Hose ID Hose OD Pressure Pressure Bend Radius Weight Inches kPa
inch mm inch mm psi MPa psi MPa inch mm lbsft kgm of Hg abs
CGH5 14 63 058 15 500 35 2000 140 1 25 019 028 20 33
CGH6 516 8 068 17 500 35 2000 140 1 14 30 023 034 20 33
CGH8 1316 10 077 20 500 35 2000 140 1 34 45 028 042 20 33
CGH10 12 125 092 23 500 35 2000 140 2 14 55 039 058 20 33
CGH12 58 16 108 27 500 35 2000 140 2 34 70 047 070 20 33
CGH16 78 22 123 31 500 35 2000 140 3 12 90 041 061 20 33
Racor marine hose for fuel oil and hydraulic fluids is fire resistant and meets SAE J1527 Type A class and SAE J1942 standards This
hose delivers testproven performance in a wide operating temperature range constant working pressure in popular sizes construction kink and cut
resistance and compatibility with a variety of standard 100R5 and synthetic rubber tube with one braid of hightensile steel wire and a weather and
fire resistant synthetic blue
rubber cover The layline is embossed for permanent Skive
1 Assembly of NoSkive hose and fittings does not require removal of outer cover of hose This eliminates premature hose failure
caused by skiving too long or short and protects vulnerable wire wrap during fitting assembly
2 Cushion grip increases hose life supporting cushion of compressed rubber between gripping threads on fitting reduces wire
movement minimizing stress
3 Corrosion protection steel wire braid of NoSkive hose is never exposed because outer rubber cover is not removed before
assembling fitting
4 NoSkive fittings are designed to allow socket threads to penetrate outer cover of hose and grip the wire braid of the hose
5 Simple two step assembly attached socket to hose thread nipple to and Temperature Range
Low pressure service hose for use with gasoline ethanol blends diesel fuels hydraulic fluids and lubricating oils within
a temperature range of 4oF to 212oF 20oC to 100oC Water waterglycol and wateroil emulsion hydraulic fluids up to 185oF 85oC
Meets Class 1 permeation requirements with gasoline and blends and passed a 2 12 minute fire test USCG accepted
for commercial and recreational vessel Fittings
Part Number Hose Size Part Number Hose Size
2082055 SAE5 2082088 SAE8
2082066 SAE6 208201010 SAE10
Marine Accessories Steel Fuel Port Fittings are now available
see the following page
Water Probe Detection Kits
Not for use with gasoline Part No Description Notes Use with Qty
RK21069 Water Probe Kit 1 each For all models with
Heat shield or metal bowl 1 Water Probe with Builtin 12 or 24vdc
Detection Electronics and Connector Kit
Includes underdash warning light kit For all models except
UL Approved for use with diesel only 500MA 500MAP 1 Underdash mount Water Detection
Module 12 vdc light only
Probe not included For all models 1
RK20726 2 Gauge Water Detection Module RK20725
12 or 24 vdc light and audio
Probe not included For all models 1
RK30056 2 Gauge Water Detection Module For all models
RK20726 and Water Probe with water sensor
RK21069 port in bowl 1
RK30743 2 Gauge Water Detection Module
RK20726 and Water Probe For Engine
RK21069 and Metal Bowl Spinon Series 1 Compound Gauge Kits
Kit Part No Description Notes Use with Qty
1606B Vacuum 030 Hg2 dial
Silicone dampened with 14NPT back mount
For instrument panel installation For vacuum
4 hose not included 1 applications 1
18 14
Adapter fitting straight 14NPTM
X 18NPTF 1
72324 Adapter fitting 18NPTM
X 4 hose 1 010242 1
72344 Adapter fitting 14swivel X 4 hose 1 For all gauges 1
THandle Replacement Vacuum Gauge Kit
Includes Silicone dampened gauge 111676
030 inHg lid fitting 111668 and Oring For vacuum
11350 Replaces original THandle applications 1 11350
Compound Vacuum 025 RK111669
Pressure 015 2 dial 14NPT
bottom mount UL Approved replacement MAX all applications 1 RK19476
1 Rubber hose is suitable for 15 feet or less otherwise rigid plastic tubing is recommended to obtain accurate Shut off Drain Valve Kit
Laboratories Marine Listed USCG Part No Description Notes Use with Qty
RK19492 Diesel Marine Shutoff Valve Kit All brass
construction Features 14NPTM to bowl or RK19492
adapter with a 14NPTF bottom port for use For all
with provided 14NPTM plug diesel
Plug must be in valve unless servicing applications 1
Marine Accessories Fittings
100 200 300 400 600 Series Fittings Package quantity is 10 pcs
Plated Steel Plugs
Yellow Zinc Part No Old Part No Thread 1
T1 918 NPT Plug
918N4 None 1418
918N6 None 3818
Plated Steel Fittings
Yellow Zinc Part No Old Part No Thread 1 Hose 2 Tube or Hose T1 913 NPT Beaded
SAEJ476 Size Number Elbow
913N4H6 New 1418 38 6
913N6H6 New 3818 38 6
911N4H6 New 1418 38 6
911N6H6 New 3818 38 6 T1
911N6H8 New 3818 12 8 H2 911 NPT Barbed
Straight
Models Models 220RMAM 225RMAM
The 220RMAM has been replaced by the new 200 Series The circled number corresponds to the item number
shown below
ItemPart No Description Case Qty
2 3 1 RK20046 Head 14 NPT Ports 1
1 4
RK20025
RK20011
RK20742
Primer Pump Assembly
Check Ball and Plastic Cap
Metal Check Ball Cap
4 RK10110 Metal Vent Plug 3816 SAE 1
5 RK12041 Metal Port Plug 14 NPT 10
6 R24SUL 220RMAM Replacement Element
2 Micron UL Recognized shown 12
R26SUL 225RMAM Replacement Element
2 Micron UL Recognized 12
7 RK20357 Metal Bowl and 38 NPT standard 1
7 8 RK20022 Metal Plug 1220 SAE 1
9 01SP6S Metal Plug 38 NPT 1
9 8 RK20128 Metal Drain Knob Seal 1
RK20075 Complete Kit 1
7238 Installation Instructions 220RMAM 225RMAM

Ad by Google

Disclaimer:
The information on this web site has not been checked for accuracy. It is for entertainment purposes only and should be independently verified before using for any other reason. There are five sources. 1) Documents and manuals from a variety of sources. These have not been checked for accuracy and in many cases have not even been read by anyone associated with L-36.com. I have no idea of they are useful or accurate, I leave that to the reader. 2) Articles others have written and submitted. If you have questions on these, please contact the author. 3) Articles that represent my personal opinions. These are intended to promote thought and for entertainment. These are not intended to be fact, they are my opinions. 4) Small programs that generate result presented on a web page. Like any computer program, these may and in some cases do have errors. Almost all of these also make simplifying assumptions so they are not totally accurate even if there are no errors. Please verify all results. 5) Weather information is from numerious of sources and is presented automatically. It is not checked for accuracy either by anyone at L-36.com or by the source which is typically the US Government. See the NOAA web site for their disclaimer. Finally, tide and current data on this site is from 2007 and 2008 data bases, which may contain even older data. Changes in harbors due to building or dredging change tides and currents and for that reason many of the locations presented are no longer supported by newer data bases. For example, there is very little tidal current data in newer data bases so current data is likely wrong to some extent. This data is NOT FOR NAVIGATION. See the XTide disclaimer for details. In addition, tide and current are influenced by storms, river flow, and other factors beyond the ability of any predictive program.