                                                               Régulateur de charge
                                                               NCC1
                                                               Le régulateur NCC1 est un régulateur de type série de 12




                                                                                                                              Naps France S.A. | 35 allée du 12 février 1934 Noisiel F-77437 Marne-la-Valléee Cédex 2 | tel. (01) 60.37.35.60 | fax (01) 60.37.84.11 | www.napssystems.com
                                                               volts qui a fait ses preuves dans les systèmes
                                                               d'installations solaires pour les résidences secondaires
                                                               et de vacances ainsi que dans d'autres systèmes
                                                               d'éclairage solaire utilisant des batteries au plomb
                                                               ouvert.
                                                               Equipé de trois entrées solaires et de trois sorties
                                                               utilisation protégées chacune par fusible, le NCC1 permet
                                                               une connexion simple du système et facilite l'extension
                                                               de l'installation progressivement. Le régulateur NCC1
                                                               contrôle le courant solaire total pouvant aller jusqu'à 10
Le régulateur NCC1 est garanti pendant un an à compter de la
date d'achat.
                                                               Ampères et les utilisations pouvant consommer au total
                                                               jusqu'à 16 Ampères.
                                                               La face avant du régulateur permet de visualiser par LED
                                                               l'état de courant de charge, l'état de charge de la
                                                               batterie, ainsi qu'un indicateur de l'état des fusibles pour
                                                               chaque utilisation.
                                                               Le courant maximum des modules solaires transite par
                                                               un relais vers la batterie jusqu'à ce que la tension haute
                                                               soit atteinte.
                                                               Il est possible de passer en mode charge forcée par un
                                                               interrupteur si la batterie a été profondément
                                                               déchargée. Ceci déplacera le point de tension seuil haut.
                                                               Si la batterie atteint un seuil de décharge profond, un
                                                               relais permet la déconnexion des circuits utilisation. Le
                                                               mode charge forcée doit alors être initialisé
                                                               manuellement. Le courant des circuits utilisation sera
                                                               restauré après avoir appuyé sur l'interrupteur de
                                                               réinitialisation.
                                                               Si le système n'est pas utilisé pendant une longue
                                                               période, un interrupteur général permet la déconnexion
                                                               de toutes les utilisations. Dans ce cas, les modules
                                                               poursuivent la charge de la batterie.
                                                               Chaque entrée solaire possède une diode anti-retour
                                                               schottky à faible perte afin d'éviter les inversions de
                                                               courants pendant la nuit.

                                                               Caractéristiques

                                                               Charge normale
                                                               La charge maximale et l'agitation de l'acide est assurée
                                                               en permettant à la tension de la batterie d'atteindre
                                                               momentanément une tension relativement élevée. Des
                                                               tests ont montré que des tensions de fin de charge plus
                                                               faibles pour des régulateurs de charge standard ont pour
                                                               conséquence la stratification de l'acide réduisant la
                                                               capacité et la durée de vie de la batterie.
Mode charge forcée                                                                                    SOLAR
                                                                                                       Modules
                                                                                                                            1      2         3
                                                                                                      MODULES
                                                                                                       solaires
La sélection manuelle de la fonction charge forcée après
                                                                                                                         +PAN1- +PAN2- +PAN3-    +BAT-   +1-    +2-      +3-
une décharge profonde permet d'éviter les problèmes de
sulfatation et de stratification.

                                                                                                                                                                                     Circuit
Trois entrées solaires




                                                                                                                                                                                                           Naps France S.A. | 35 allée du 12 février 1934 Noisiel F-77437 Marne-la-Valléee Cédex 2 | tel. (01) 60.37.35.60 | fax (01) 60.37.84.11 | www.napssystems.com
                                                                                                                                                                               utilisation  1 1
                                                                                                                                                                                   LOAD CIRCUIT


permettent une connexion simple de trois modules                                                                                                                                       Circuit
                                                                                                                                                                                      LOAD CIRCUIT 2
                                                                                                                                                                                utilisation 2
solaires à n'importe quel moment, y compris des modules                                                                         FUSE                                           LOAD CIRCUIT 3
                                                                                                                                 FusibleMAX                           Circuit utilisation 3
de courant différent. Chaque entrée solaire est de 5                                                                            16 AMPS
                                                                                                                                 max. 16 A
Ampères maximum et acceptera en toute sécurité un                                                                                                                   MAXIMUM
                                                                                                                                                               Courant             LOAD,
                                                                                                                                                                         max. utilisation,
                                                                                                                                                                    CIRCUITS
                                                                                                                                                               circuits 1/2/3 16 A1+2+3
module de 50 ou de 75 Watts. Un module de courant plus                                                                                   +               -
                                                                                                                                                                      16 Amps
élevé (par exemple de 100 Watts et de 6 Ampères                                                                                              Batterie
approximativement) peut être utilisé s'il est connecté sur                                                                                   BATTERY

deux entrées solaires.
                                                                                                  Caractéristiques électriques du NCC1
Protection des courants inverses                                                                  Tension nominale 12 V
                                                                                                  Tension maximale du panneau solaire 25 V
Une diode intégrale de blocage SCHOTTKY sur chaque
entrée solaire empêchera la batterie de se décharger                                              Courant solaire maximum 10 A
vers le champ solaire pendant la nuit.                                                            Courant solaire maximum par entrée 5 A
                                                                                                  Courant maximum d'utilisation 16 A
Trois circuits utilisation avec fusibles                                                          Courant maximum par sortie utilisation 10 A
Le régulateur NCC1 possède trois circuits utilisation ,                                           En charge normale 14,9 V
chacun doté d'un fusible de 10 Ampères. Néanmoins, les                                            Seuil de régulation 13,4 V
utilisations ne doivent pas dépasser 16 Ampères. Si un                                            En charge forcée 15,6 V
fusible est défectueux, un indicateur de type LED
                                                                                                  Seuil de disparition 13,8 V
s'allume sur la face avant du régulateur. De plus, il est
recommandé d'installer un fusible de 16 Ampères                                                   Seuil de délestage de l'utilisation 11,4 V
séparément sur le câble batterie.                                                                 Reconnexion des utilisations par interrupteur manuel
                                                                                                  Indicateur de l'état de charge de la batterie
Protection contre la décharge profonde de la
                                                                                                  -     vert > 12 V
batterie
                                                                                                  -     jaune 11,5 ­ 12 V
Une batterie complètement déchargée pourrait s'abîmer                                             -     rouge < 11,5 V
et geler en hiver. Le régulateur NCC1 possède un circuit
de protection de tension basse qui déconnecte les
utilisations de la batterie en cas de décharge profonde.                                          Consommation (typique)
Une fois que la tension de la batterie a augmenté                                                 -     en charge 8 mA
suffisamment, l'interrupteur de réinitialisation                                                  -     en régulation haute 50 mA
reconnectera les utilisations.
                                                                                                  -     en délestage 8 mA

Indication de l'état de charge de la batterie
                                                                                                  Plage de température de fonctionnement
En mettant l'interrupteur sur la position «test», une des
trois LED s'allume pour indiquer la tension batterie. En                                          20°C à + 50°C
position «test» la batterie est déconnectée des modules
solaires et des utilisations et, si la batterie est chargée                                       Dimensions
ou déchargée, l'interrupteur doit rester en position                                              Régulateur seul 177 x 118 x 36 mm
«test» pendant au moins une minute afin d'obtenir une
indication fiable.                                                                                Régulateur emballé 190 x 124 x 40 mm
                                                                                                  Poids Régulateur seul 0,275 KG
Facilité de connexion                                                                             Régulateur emballé 0,34 KG

Facilement accessibles et standardisées des vis
admettent des sections de câbles jusqu'à 4 mm2 à
                                                                                                  Options (Code produit)
l'arrière des modules, de l'utilisation et de la batterie.                                        40000                NCC1 face avant en finnois
                                                                                                  40001                NCC1 face avant en anglais

Ces spécifications peuvent être modifiées sans préavis du fait de la politique de Naps Systems Oy 'amélioration continue des produits.


                                                                                                                                                                                     FR-SE-PI116-1-01/01


Ad by Google

Disclaimer:
The information on this web site has not been checked for accuracy. It is for entertainment purposes only and should be independently verified before using for any other reason. There are five sources. 1) Documents and manuals from a variety of sources. These have not been checked for accuracy and in many cases have not even been read by anyone associated with L-36.com. I have no idea of they are useful or accurate, I leave that to the reader. 2) Articles others have written and submitted. If you have questions on these, please contact the author. 3) Articles that represent my personal opinions. These are intended to promote thought and for entertainment. These are not intended to be fact, they are my opinions. 4) Small programs that generate result presented on a web page. Like any computer program, these may and in some cases do have errors. Almost all of these also make simplifying assumptions so they are not totally accurate even if there are no errors. Please verify all results. 5) Weather information is from numerious of sources and is presented automatically. It is not checked for accuracy either by anyone at L-36.com or by the source which is typically the US Government. See the NOAA web site for their disclaimer. Finally, tide and current data on this site is from 2007 and 2008 data bases, which may contain even older data. Changes in harbors due to building or dredging change tides and currents and for that reason many of the locations presented are no longer supported by newer data bases. For example, there is very little tidal current data in newer data bases so current data is likely wrong to some extent. This data is NOT FOR NAVIGATION. See the XTide disclaimer for details. In addition, tide and current are influenced by storms, river flow, and other factors beyond the ability of any predictive program.